Intel® Server Chassis SC5650-DP/WS/BRP/UP Service Guide A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/Products Intel Order Number E55434-004
Disclaimer Information in this document is provided in connection with Intel® products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document.
Safety Information Important Safety Instructions Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the Intel® Server Deployment Toolkit CD and/or at http://support.intel.com/support/ motherboards/server/sb/cs-010770.htm/. Wichtige Sicherheitshinweise Lesen Sie zunächst sämtliche Warnund Sicherheitshinweise in diesem Dokument, bevor Sie eine der Anweisungen ausführen.
Safety Information Warnings Heed safety instructions: Before working with your server product, whether you are using this guide or any other resource as a reference, pay close attention to the safety instructions. You must adhere to the assembly instructions in this guide to ensure and maintain compliance with existing product certifications and approvals. Use only the described, regulated components specified in this guide.
Preface About this Manual Thank you for purchasing and using the Intel® Server Chassis SC5650. This manual is written for system technicians responsible for troubleshooting, upgrading, and repairing this server chassis. This document provides a brief overview of the features of the chassis, a list of accessories or other components you may need, troubleshooting information, and instructions on how to add and replace components on the Intel® Server Chassis SC5650.
Preface • Fan cable, installed in the chassis • Chassis intrusion switch, installed in the chassis • Front panel, installed in the chassis • • • • • Attention document, in the chassis product box Intel® Server Chassis SC5650 Quick Start User's Guide, in the chassis product box Four M3 screws for installing 5.
Preface For this information or software Use this Document or Software For virtual system tours and interactive repair information A link to the Intel® Server Configurator tool is available under "Other Resources" at the right side of the screen at: Accessories or other Intel server products Spares and Configuration Guide Hardware (peripheral boards, adapter cards, and so forth) and operating systems that were tested with this product Tested Hardware/Operating Systems List To make sure your system
Preface viii Intel® Server Chassis SC5650-DP/WS/BRP/UP Service Guide
Contents Safety Information ..................................................................................................... iii Important Safety Instructions ................................................................................................ iii Wichtige Sicherheitshinweise ............................................................................................... iii Consignes de sécurité ................................................................................................
Removing a CD-ROM or DVD-ROM Drive ................................................................. 35 Installing and Removing PCI Add-in Boards ....................................................................... 36 Installing PCI Add-in Boards ....................................................................................... 36 Removing PCI Add-in Boards ..................................................................................... 38 Replacing the Front Panel Board .......................
Sicherheitshinweise für den Server ...........................................................................103 Sicherheitshinweise und Vorsichtsmaßnahmen ........................................................103 Zielbenutzer der Anwendung .....................................................................................104 Standortauswahl ........................................................................................................104 Handhabung von Geräten ................................
Product Regulatory Compliance ........................................................................................ 147 Product Safety Compliance ....................................................................................... 147 Product EMC Compliance - Class A Compliance ..................................................... 148 Certifications / Registrations / Declarations .............................................................. 149 Product Regulatory Compliance Markings .................
List of Figures Figure 1. Front View of Intel® Server Chassis SC5650.............................................................. 1 Figure 2. Front View Components (with Front Bezel Assembly)................................................ 3 Figure 3. Front View Components (without Front Bezel Assembly)........................................... 4 Figure 4. Internal Components (DP/WS/BRP Configuration Shown)......................................... 5 Figure 5. Back Panel Components.........................
Figure 40. Opening PCI Add-in Card Retention Device (DP/WS/BRP configuration shown) .. 37 Figure 41. Removing PCI Slot Shield ...................................................................................... 37 Figure 42. Installing PCI Add-in Board..................................................................................... 38 Figure 43. Opening PCI Add-in Card Retention Device (DP/WS/BRP configuration shown) .. 39 Figure 44. Removing PCI Add-in Board...........................................
Figure 85. Attaching Fan to Fan Bracket Non-Expanded, Hot Swap Drive Cage .................... 69 Figure 86. Inserting Hot Swap Drive Cage into Chassis (DP/WS/BRP configuration shown).. 70 Figure 87. Layout of Cable Connectors on the SAS/SATA Backplane (Backplane without expander shown).................................................................................................................... 72 Figure 88.
xvi Intel® Server Chassis SC5650-DP/WS/BRP/UP Service Guide
List of Tables Table 1. Breakdown of Intel® Server Chassis SC5650 Configurations ...................................... 1 Table 2. Server Chassis Features.............................................................................................. 2 Table 3. Accessories and Order Codes ................................................................................... 11 Table 4. DP 600-W Power Supply Output Capability ............................................................... 95 Table 5.
xviii Intel® Server Chassis SC5650-DP/WS/BRP/UP Service Guide
1 Server Chassis Features This chapter describes the main features of the Intel® Server Chassis SC5650. The location of important chassis components and connections, as well as a description of LED identification, are also presented. AF000307 Figure 1. Front View of Intel® Server Chassis SC5650 The Intel® Server Chassis SC5650 is a 5.2U pedestal1 server chassis and is available in three configurations: DP (dual-processor), WS (workstation), BRP (base redundant power) and UP(single-processor).
Server Chassis Features NOTES: 1. For updated server board support, go to: http://support.intel.com/support/motherboards/server/ chassis/sc5650/ Table 2 summarizes the features of the Intel® Server Chassis SC5650. Table 2.
Server Chassis Features Table 2. Server Chassis Features Intel® Server Chassis SC5650BRP Configuration Intel® Server Chassis SC5650DP Dimensions Pedestal 17.8 in (45.2 cm) x 9.256 in (23.5 cm) x 19 in (48.3 cm) Dimensions Rack 9.256 in (23.5 cm) x 17.6 in (44.7 cm) x 19 in (48.3 cm) Intel® Server Chassis SC5650WS Intel® Server Chassis SC5650UP Component Identification Front View Components A B C D E TP02345 A. 5.25-in Device Drive Bays B. Front Panel C. Drive Bay Access Door D. Door Lock E.
Server Chassis Features A B C D E TP00882 A. 5.25-in Device Drive Bays B. 3.5-in Device Drive Bay C. Hard Drive Cage D. Drive Bay EMI Shield (shown open) E. Front Panel USB Ports Figure 3.
Server Chassis Features Internal Components A B J LOCK C I WARNING: IMPROPER INSTALLATION & REMOVAL OF DUCT CAN CAUSE DAMAGE TO THE SERVER BOARD. INSTALL & REMOVE THE DUCT WITH CAUTION REMOVE FOR DUAL CPU OPERATION D E F H G AF002995 A. Tool-less Device Bay Locks B. 5.25-in Device Bays C. 3.5-in Device Bay D. Drive Bay EMI Shield E. Drive Cage Retention Mechanism F. PCI Add-in Card Guide G. Front Panel USB Ports H. Rear Tool-less PCI Retention Mechanisms I. Fan Duct / System Fan Assembly J.
Server Chassis Features Back Panel Components 6 Intel® Server Chassis SC5650-DP/WS/BRP/UP Service Guide
Server Chassis Features A. Power Supply NOTE: Fixed Power Supply shown. Your Power Supply may vary depending on chassis configuration purchased B. A/C Power In NOTE: Fixed Power Supply shown. Your Power Supply may vary depending on chassis configuration purchased. C. I/O Shield NOTE: I/O connectors vary, depending on the server board installed. See your server board documentation for port identification. D. PCI Add-in Card slots E. External SCSI knockout F. System Fan G. Serial B port knockout (UP only) H.
Server Chassis Features Callout A. Feature1,2 Power/Sleep LED Function Continuous green light indicates the system has power applied to it. Continuous amber light indicates the system is in S1 Sleep state. No light indicates the power is off / or the system is in S4 Sleep state. B. Power Button Powers the system off or on. C. NMI Button Used to force system halt and dump memory contents to screen or file. D. Reset Button Reboots and initializes the system. E. F.
Server Chassis Features NOTE: It is recommended that screws be used to secure large devices if shipping chassis integrated. Figure 7. Optional Peripheral Devices (DP/WS/BRP configuration shown) Hard Disk Drives The server chassis ships with one fixed hard drive cage capable of supporting up to six cabled 3.5-in x 1-in hard drives. Power requirements for each individual hard drive may limit the maximum number of drives that can be integrated into the server chassis.
Server Chassis Features Note: Drives can consume up to 18.4 watts of power each. Drives must be specified to run at a maximum ambient temperature of 45C. Note: The Intel® Server Chassis SC5650 does not support all Serial ATA hard drives. See “Additional Information and Software” for a web link to a list of supported hardware. Front Bezel Assembly The front bezel assembly provides a snap-on design that allows for maximum airflow through the server chassis.
Server Chassis Features Mechanical Locks All configurations of the server chassis can support the installation of a padlock loop (see letter “A” in the following figure) at the rear of the chassis. Additionally, the server chassis ships with a two-position mechanical lock (see letter “B”) on the front bezel assembly to prevent access to the hard drives and the interior of the chassis. B A AF000308 Figure 8.
Server Chassis Features 12 Intel® Server Chassis SC5650-DP/WS/BRP/UP Service Guide
2 Hardware Installations and Upgrades This document provides instructions for adding and replacing chassis components. For instructions on replacing components on the server board, such as the processor and memory DIMMs, see the instructions provided with the server board. Before You Begin Before working with your server product, review the important safety information listed in Appendix A, “Safety Information”.
Hardware Installations and Upgrades 4. If present, remove the two screws (see letter “A” in the following figure). Push in on the latch with your right hand (see letter “B”), and with your left hand, grasp the rear cover clasp and slide the left side cover rearward to remove from chassis (see letter “C”). A B C A TP00559 Figure 9. Removing Left Side Cover Installing the Left Side Cover Warning: This chassis must be operated with the left side cover installed to ensure proper cooling. 1.
Hardware Installations and Upgrades Removing and Installing the Right Side Cover Warning: This chassis must be operated with the right side cover installed to ensure proper cooling Removing the Right Side Cover 1. Observe the safety and ESD precautions listed in Appendix A, “Safety Information”. 2. Power down the server and unplug all peripheral devices and the AC power cable. 3. Remove the left side cover. For instructions, see “Removing the Left Side Cover”. 4.
Hardware Installations and Upgrades Installing the Right Side Cover 1. Reinstall the right side cover. Reinstall the two screws. Warning: This chassis must be operated with the right side cover installed to ensure proper cooling. TP01741 Figure 12. Re-installing Right Side Cover on Chassis 2. Reinstall the front bezel assembly. For instructions, see “Installing the Front Bezel Assembly”. 3. Reinstall the left side cover. For instructions, see “Installing the Left Side Cover” 4.
Hardware Installations and Upgrades Removing and Installing the Front Bezel Assembly All configurations of the Intel® Server Chassis SC5650 ship with a two-piece front bezel assembly. Removing the Front Bezel Assembly 1. Observe the safety and ESD precautions listed in Appendix A, “Safety Information”. 2. Turn off all peripheral devices connected to the server. Turn off the server. 3. Disconnect the AC power cord. 4. Remove the left side cover. For instructions, see “Removing the Left Side Cover”. 5.
Hardware Installations and Upgrades Installing the Front Bezel Assembly 1. Line up the three clips on the right side of the front bezel assembly with the corresponding slots on the right side of the chassis (see letter “A” in the following figure). Engage the clips with the slots (see letter “B”). Rotate the left side of the front bezel assembly towards the chassis (see letter “C”). Snap the two bezel tabs into the corresponding recesses at the left edge of the chassis front panel (see letter “D”).
Hardware Installations and Upgrades 5. Loosen thumb screw and remove the drive cage EMI shield (see letter “A” in the following figure). A B TP01869 Figure 15. Removing Drive Cage EMI Shield from Fixed Drive Cage (DP/WS/BRP configuration shown) 6. Disconnect cables from any installed fixed hard drives. If necessary, remove hard drives from fixed hard drive cage. For instructions on removing fixed hard drives, see “Removing a Fixed Hard Drive”.
Hardware Installations and Upgrades 7. Push the blue plastic release mechanism upward to release the fixed hard drive cage (see letter “A” in the following figure). Once released, pull the fixed hard drive cage from the chassis (see letter “B”). A B TP02038 Figure 16. Removing Fixed Hard Drive Cage (DP/WS/BRP configuration shown) 8. Remove any PCI add-in boards that are present. 9.
Hardware Installations and Upgrades 10. If installing a server board, refer to your Intel® Server Board User’s Guide and/or Quick Start User’s Guide for installation instructions. Use the mounting screws, bumpers and standoffs (if necessary) that came with your chassis to secure the server board to the chassis. Make sure the server board is properly seated and then tighten the screws firmly, starting with the screws at the center of the server board.
Hardware Installations and Upgrades 12. Slide the fixed hard drive cage into the drive bay slot of the chassis. You should hear a click when the blue plastic retention mechanism locks into place. TP02039 Figure 19. Inserting Fixed Hard Drive Cage into Chassis (DP/WS/BRP configuration only) 13. If previously removed, install fixed hard drives and connect power and data cables. For instructions, see “Installing a Fixed Hard Drive”.
Hardware Installations and Upgrades 14. Re-attach the drive cage EMI shield to the fixed hard drive cage and tighten the thumb screw. AF000315 Figure 20. Re-attaching Drive Cage EMI Shield 15. Re-install the front bezel assembly. For instructions, see “Removing and Installing the Front Bezel Assembly” 16. Re-install the left side cover. For instructions, see “Installing the Left Side Cover” 17. Plug all peripheral devices and the AC power cable(s) back into the server. Power up the server.
Hardware Installations and Upgrades Installing and Removing a Fixed Hard Drive You can install up to six fixed hard drives in the fixed hard drive cage that ships with the Intel® Server Chassis SC5650. Power requirements for each individual hard drive may limit the maximum number of drives that can be integrated into the server chassis. Note: The Intel® Server Chassis SC5650 does not support all hard drives. See “Additional Information and Software” for a web link to a list of supported hard drives.
Hardware Installations and Upgrades 3. Remove the left side cover. For instructions, see “Removing the Left Side Cover”. 4. Remove the front bezel assembly. For instructions, see “Removing the Front Bezel Assembly”. 5. Loosen thumb screw and remove the drive cage EMI shield (see letter “A” in the following figure). A B TP01869 Figure 22. Removing Drive Cage EMI Shield from Chassis (DP/WS/BRP configuration shown) 6. Remove any PCI add-in boards that use the PCI card guide.
Hardware Installations and Upgrades 7. Remove the PCI card guide by pressing in on the blue tabs (see letter “A” in the following figure) and pulling the PCI card guide outward (see letter “B”). A B TP01732 Figure 23. Removing PCI Card Guide 8. Route the required power cables (connectors P7-P10 for DP/BRP/WS, P6-P8 and P10-P12 for UP) from behind the PCI card guide through the cable routing area at the bottom of the fixed drive cage. AF000317 Figure 24.
Hardware Installations and Upgrades 9. Pull the drive latch forward to unlatch the drive locking assembly for the drive bay you want to install a hard drive in. AF000318 Figure 25. Unlatching Drive Latch 10. Insert fixed hard drive into drive bay and push until it stops. Ensure the power and data connector end of the hard drive are facing forward. AF000319 Figure 26.
Hardware Installations and Upgrades 11. Push drive latch in to lock hard drive into drive bay. AF000320 Figure 27. Latching Drive Latch 12. Install additional drives as necessary. Warning: You MUST populate drive bay slots 1, 3, and 5 first. Failure to do so could result in thermal issues within the chassis. 1 2 3 4 5 6 AF000316 Figure 28.
Hardware Installations and Upgrades 13. Install power (see letter “A” in the following figure) and data (see letter “B”) cables to each of the installed drives.The cables route through the oval opening at the bottom of the fixed drive cage. A B AF000429 Figure 29. Cabling a Fixed Hard Drive 14. Re-attach the drive cage EMI shield to the chassis and tighten the thumb screw. AF000315 Figure 30.
Hardware Installations and Upgrades 15. Re-install the PCI card guide. Insert tabs on the left side of PCI card guide into slots in chassis (see letter “A” in the following figure). Swing PCI card guide into chassis until right-side blue tabs snap into place (see letter “B”). A B TP01735 Figure 31. Re-installing PCI Card Guide 16. Re-install any PCI add-in cards that were removed. For instructions, see “Installing PCI Add-in Boards”. 17. Re-install the front bezel assembly.
Hardware Installations and Upgrades 5. Loosen thumb screw (see letter “A” in the following figure). Apply slight pressure to the right side of drive bay access door and swing door outward (see letter “B”). A B TP01869 Figure 32. Removing Drive Cage EMI Shield from Chassis (DP/WS/BRP configuration shown) 6. Disconnect the data and power cables from the hard drive to be removed (see letter “A” in the following figure).
Hardware Installations and Upgrades 7. Slide the hard drive out of the fixed hard drive cage and place the hard drive on an anti-static surface. If replacing the hard drive, see “Installing a Fixed Hard Drive” for instructions. AF000431 Figure 34. Removing Fixed Hard Drive from Drive Bay 8. Re-attach the drive cage EMI shield to the chassis and tighten the thumb screw. AF000315 Figure 35. Re-installing Drive Cage EMI Shield 9. Re-install the front bezel assembly.
Hardware Installations and Upgrades 11. Plug all peripheral devices and the AC power cable(s) into the server. Power up the server. Installing or Removing a DVD-ROM or CD-ROM Drive Caution: CD-ROM and DVD-ROM drives are NOT hot-swappable. Before removing or replacing the drive, you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and unplug the AC power cord from the system or wall outlet.
Hardware Installations and Upgrades 6. Insert the CD-ROM or DVD-ROM drive into the 5.25-in device drive bay (see letter “C” in the following figure). Line up holes in CD-ROM drive with holes in chassis (see letter “D”). Move latch to the “lock” position (see letter “E”). Connect power (P5 or P6connector from the power supply. An additional 4-pin IDE male-to SATA 15poin power cables adapter may be needed if the CD-ROM or DVD-ROM does not have a 4-pin power connector.
Hardware Installations and Upgrades 8. Reinstall the front bezel assembly. For instructions, see “Installing the Front Bezel Assembly”. 9. Reinstall the left side cover. For instructions, see “Installing the Left Side Cover”. 10. Reconnect all peripheral devices and the AC power cable(s). Power up the server. Removing a CD-ROM or DVD-ROM Drive 1. Observe the safety and ESD precautions listed in Appendix A, “Safety Information”. 2.
Hardware Installations and Upgrades 6. If reinstalling a new CD-ROM or DVD-ROM drive, see “Installing a DVD-ROM or CD-ROM Drive” for instructions. If not replacing the drive, reinstall the EMI shield and front bezel filler panel, if available. TP02048 Figure 39. Installing 5.25-in Drive EMI Shield (DP/WS/BRP configuration shown) 7. Reinstall the front bezel assembly. For instructions, see “Installing the Front Bezel Assembly”. 8. Reinstall the chassis cover.
Hardware Installations and Upgrades 3. Remove the left side cover. For instructions, see “Removing the Left Side Cover”. 4. Open the back panel PCI Add-in Card Retention Device by pressing open from the inside of the chassis. TP02049 Figure 40. Opening PCI Add-in Card Retention Device (DP/WS/BRP configuration shown) 5. If it is already not removed, remove the PCI slot shield by pushing the shield out from the inside of the chassis. TP01744 Figure 41. Removing PCI Slot Shield 6.
Hardware Installations and Upgrades 7. Hold the PCI add-in board by its top edge or upper corners. Firmly press the add-in board into an expansion slot on the server board (see letter “A” in the following figure). Close the back panel PCI Add-in Card Retention Device (see letter “B”). BB A TP01745 Figure 42. Installing PCI Add-in Board 8. Repeat the previous steps until all PCI add-in boards are installed. 9. Attach cables, if necessary. 10. Reinstall the left side cover.
Hardware Installations and Upgrades 4. Open the back panel PCI Add-in Card Retention Device by pressing open from the inside of the chassis. TP02049 Figure 43. Opening PCI Add-in Card Retention Device (DP/WS/BRP configuration shown) 5. Disconnect any cables that may be attached to the PCI add-in board that needs to be removed. 6. Firmly grab the PCI add-in board by its top edge or upper corners and remove from the expansion slot on the server board (see letter “A” in the following figure).
Hardware Installations and Upgrades 7. If available, replace the PCI slot shield by pressing the slot shield into the opening on the chassis. TP01726 Figure 45. Replacing PCI Slot Shield 8. Reinstall the left side cover. For instructions, see “Installing the Left Side Cover”. 9. Reconnect all peripheral devices and the AC power cable(s). Power up the server. Replacing the Front Panel Board Your server must be operated with a front panel board installed.
Hardware Installations and Upgrades 5. Remove the two screws (see letter “A” in the following figure”) securing the right side cover to the chassis. Lift the right side cover off the chassis. A A TP01736 Figure 46. Removing Right Side Cover from Chassis 6. Remove the three screws securing the front panel board to the chassis. TP01737 Figure 47.
Hardware Installations and Upgrades 7. Carefully remove the front panel board through the opening in the left side of the chassis (see letter “A” in the following figure). Disconnect the front panel cable (see letter “B”) and the chassis intrusion cable (see letter “C”) from the front panel board. A B C AF000432 Figure 48. Removing Front Panel Board from Chassis 8. Remove standoffs from the old front panel and install on the new front panel. TP02000 Figure 49.
Hardware Installations and Upgrades 9. Attach the front panel cable (see letter “A” in the following figure) and the chassis intrusion cable (see letter “B”) to the new front panel board. Slide the new front panel board through the opening in the left side of chassis (see letter “C”). C A B AF000433 Figure 50. Installing Front Panel Board in Chassis 10. Use one hand to align the front panel board in position inside the chassis.
Hardware Installations and Upgrades 11. Reinstall the right side cover. Reinstall the two screws. Warning: This chassis must be operated with the right side cover installed to ensure proper cooling. TP01741 Figure 52. Re-installing Right Side Cover on Chassis 12. Reinstall the front bezel assembly. For instructions, see “Installing the Front Bezel Assembly”. 13. Reinstall the left side cover. For instructions, see “Installing the Left Side Cover” 14.
Hardware Installations and Upgrades 4. (For all server boards on DP/WS/BRP configuration EXCEPT Intel® Server Board S5500BC) Remove the fan duct /system fan assembly. Figure 53. Removing Fan Duct / System Fan Assembly (DP/WS/BRP configuration) 5. Disconnect the fan power cable from the server board (see letter “A” in the following figure). Remove the system fan from its snap-in bracket by pressing the two bracket tabs outward (see letter “B”). Figure 54.
Hardware Installations and Upgrades 6. (For UP configuration) Remove fan duct assembly and system fan by pushing the left and right tabs outward and disengaging from snap-in bracket. Figure 55. Removing Fan Duct / System Fan Assembly (UP configuration) 7. For Intel® Server Board S5500BC only, install the fan guard. For installation, the new system fan in the snap-in bracket is shown in the following figure. 1 3 Figure 56. Installing System Fan in Chassis 8.
Hardware Installations and Upgrades Figure 57. Re-installing Fan Duct / System Fan Assembly (DP/WS/BRP configuration) 9. For UP only, insert the system fan and fan duct assembly into the snap-in bracket on the chassis back panel. Figure 58. Re-installing Fan Duct / System Fan Assembly (UP configuration) 10. Reconnect the fan cable to the server board. Refer to the User Guide that came with your server board for connection location. 11. Install the left side cover.
Hardware Installations and Upgrades Replacing a Fixed Power Supply Warning: Hazardous conditions, power supply: Hazardous voltage, current, and energy levels are present inside the power supply. There are no user-serviceable parts inside it; servicing of the power supply should only be done by technically qualified personnel. Caution: The fixed power supply is NOT hot-swappable in the DP, UP, and WS models of the Intel® Server Chassis SC5650.
Hardware Installations and Upgrades 6. Once the fixed power supply is loose, push the power supply against the blue locking mechanism and then lift the power supply out of the chassis. TP01754 Figure 60. Removing Fixed Power Supply from Chassis 7. Insert the new fixed power supply in chassis. Ensure the blue locking mechanism is still in the open position. Make sure the new fixed power supply rests on the small metal shelf on the side wall of the chassis (see letter “A” in the following figure).
Hardware Installations and Upgrades 8. Rotate the blue locking mechanism to the locked position (see letter “A” in the following figure). A TP01755 Figure 62. Locking Fixed Power Supply into Chassis 9. Route and connect the P1, P2, P3 and P4 (for DP/BRP/WS), P1 and P2 (for UP)cables to the server board. Refer to the Intel® Server Board Quick Start User’s Guide or User Guide that came with your Intel® server board for appropriate power connections. 10.
Hardware Installations and Upgrades Installing an Additional Hot Swap Power Supply Module (BRP configuration only) Note: This install procedure only applies to a chassis with redundant power supply capability. DO NOT perform this install procedure if your chassis has a fixed power supply. Warning: Hazardous conditions, power supply: Hazardous voltage, current, and energy levels are present inside the power supply.
Hardware Installations and Upgrades Removing a Hot Swap Power Supply (BRP configuration only) Warning: Hazardous conditions, power supply: Hazardous voltage, current, and energy levels are present inside the power supply. There are no user-serviceable parts inside it; servicing of the power supply should be done only by technically qualified personnel. 1. Observe the safety and ESD precautions listed in Appendix A, “Safety Information”. 2. Remove power cable from defective power supply. 3.
Hardware Installations and Upgrades Figure 66. Inserting Hot Swap Power Supply Module in Chassis 5. Connect power cable to replaced hot swap power supply. Replacing a Hot Swap Power Supply Cage (BRP configuration only) Warning: Hazardous conditions, power supply: Hazardous voltage, current, and energy levels are present inside the power supply. There are no user-serviceable parts inside it; servicing of the power supply should be done by technically qualified personnel. 1.
Hardware Installations and Upgrades Figure 67. Removing Hot Swap Power Supply Module 5. Remove second (redundant) hot swap power supply module (or filler panel), if one is present. 6. Disconnect all internal power cables from chassis components and server board. 7. Remove two internal screws (see letter “A” in the following figure) securing hot swap power supply cage to chassis. A Figure 68. Detaching Hot Swap Power Supply Cage from Inside of Chassis 8.
Hardware Installations and Upgrades Note: You may have to work the power cables through slot openings with your free hand as you remove the power supply cage from the chassis. TP01762 Figure 69. Detaching Hot Swap Power Supply Cage from Rear of Chassis 9. Remove the two screws (see letter “A” in the following figure) attaching the rear support bracket to the old power supply cage. Remove the rear support bracket (see letter “B”). B A Figure 70.
Hardware Installations and Upgrades Figure 71. Attaching Rear Support Bracket to Power Supply Cage 11. Insert new hot swap power supply cage into chassis. Secure back of hot swap power supply cage to chassis with five screws. Note: Ensure you route the power supply cables through the power supply opening in the chassis first before inserting the power supply cage. TP01766 Figure 72. Securing Hot Swap Power Supply Cage to Rear of Chassis 12.
Hardware Installations and Upgrades A AF002934 Figure 73. Securing Hot Swap Power Supply Cage to Inside of Chassis 13. Route and connect the P1, P2, P3, and P4 cables to the server board. Refer to the Intel® Server Board Quick Start User’s Guide or User Guide that came with your Intel® server board for appropriate power connections. 14. Route the P5 and P6 cables to the PCI Express* graphic cards. 15. Route the P9 and P10 cables to the 5.25-in.
Hardware Installations and Upgrades AF002929 Figure 74. Re-installing Hot Swap Power Supply Module(s) 18. Install the left side cover. For instructions, see “Installing the Left Side Cover”. 19. Reconnect all peripheral devices and the AC power cable(s) to the server. Power up the server.
Hardware Installations and Upgrades Installing Feet for a Pedestal-configured Chassis Note: Do not install feet on your Intel® Server Chassis SC5650 if it is to be installed in a rack. Only install feet on a pedestal-configured chassis. 1. Observe the safety and ESD precautions listed in Appendix A, “Safety Information”. 2. Power down the server and unplug all peripheral devices and the AC power cable. 3. Lay the chassis down on its right side. 4.
Hardware Installations and Upgrades 60 Intel® Server Chassis SC5650-DP/WS/BRP/UP Service Guide
3 Hot Swap Drive Cage Upgrade Install Instructions (optional) The fixed hard drive cage that ships with your Intel® Server Chassis SC5650 is upgradeable to a hot swap drive cage with a SAS/SATA backplane. See your Intel Representative for ordering information. You can install up to six hot swap hard drives in the optional hot swap drive cage. Power requirements for each individual hard drive may limit the maximum number of drives that can be integrated into the server chassis.
Hot Swap Drive Cage Upgrade Install Instructions (optional) Installing a Hot Swap Hard Drive Cage with a SAS/SATA Backplane 1. Observe the safety and ESD precautions listed in Appendix A, “Safety Information”. 2. Power down the server and unplug all peripheral devices and the AC power cable. 3. Remove the left side cover. For instructions, see “Removing the Left Side Cover”. 4. Remove the front bezel assembly. For instructions, see “Removing the Front Bezel Assembly”. 5.
Hot Swap Drive Cage Upgrade Install Instructions (optional) 7. Push the blue plastic release mechanism upward to release the fixed hard drive cage (see letter “A” in the following figure). Once released, pull the fixed hard drive cage from the chassis (see letter “B”). A B TP02038 Figure 77. Removing Fixed Hard Drive Cage from Chassis (DP/WS/BRP configuration shown) 8. Gather together the components for the hot swap drive cage installation.
Hot Swap Drive Cage Upgrade Install Instructions (optional) 9. Remove the stud screws from the top of the hot swap drive cage. AF002935 Figure 78. Removing Stud Screws from Hot Swap Drive Cage 10. Attach the latch plate to the left side of the hot swap drive cage. TP01060 Figure 79.
Hot Swap Drive Cage Upgrade Install Instructions (optional) 11. Attach the side filler panel to the right side of the hot swap drive cage. TP01059 Figure 80. Attaching Filler Panel to Hot Swap Drive Cage 12. Remove the two thumb screws that secure the backplane to the hot swap drive cage. AF002936 Figure 81.
Hot Swap Drive Cage Upgrade Install Instructions (optional) 13. Align the fan bracket with the three pegs on the drive cage (see letter “A” in the following figure) and slide the fan bracket into position. Replace the two thumb screws (see letter “B”). Caution: The backplane may have slipped once the thumb screws were removed. Ensure the backplane is positioned correctly before re-tightening the thumb screws. B A B AF002937 Figure 82.
Hot Swap Drive Cage Upgrade Install Instructions (optional) A B AF003066 Figure 83.
Hot Swap Drive Cage Upgrade Install Instructions (optional) 14. Attach the fan to the fan bracket by placing two corners of the fan into the two holding slots on the fan bracket. Press the fan into the fan bracket until it clicks into place. Caution: Ensure the label and directional airflow arrow on fan are pointed out (away from the backplane). AF002940 Figure 84.
Hot Swap Drive Cage Upgrade Install Instructions (optional) AF003067 Figure 85.
Hot Swap Drive Cage Upgrade Install Instructions (optional) 15. Slide the drive cage into the drive bay slot on the chassis. You should hear a click when the blue plastic retention mechanism locks into place. Be sure to feed the fan cable through the slot first so it exits through the back of the drive cage. Connect the fan cable to its connector on the server board. TP02051 Figure 86. Inserting Hot Swap Drive Cage into Chassis (DP/WS/BRP configuration shown) 16.
Hot Swap Drive Cage Upgrade Install Instructions (optional) 17. Make the backplane and server board/RAID controller card cable connections. Cable instructions differ depending upon whether you are installing an SAS/SATA hot swap drive cage. Refer to the documentation that came with your server board and/or RAID controller card for instructions on connecting backplane cables to your server board or RAID controller card.
Hot Swap Drive Cage Upgrade Install Instructions (optional) The SAS/SATA connectors are laid out as follows on the SAS/SATA backplane. A. SATA/SAS hot-swap drive connectors B. SATA/SAS cable connectors C. SES header D. SGPIO header E. IPMB header F. Power connectors Figure 87.
Hot Swap Drive Cage Upgrade Install Instructions (optional) b. If you are installing a SAS/SATA hot swap backplane without expander: Warning: SATA controllers cannot be used with an expander backplane. i. Connect the two power cables (see letter “A” in the following figure) to the power cable connectors on the SAS/SATA backplane. ii. Connect a SAS/SATA data cable (see letter “B”) to each appropriate SAS/ SATA connector on the SAS/SATA backplane. iii. Connect the IPMB cable (see letter “C”). iv.
Hot Swap Drive Cage Upgrade Install Instructions (optional) c. If you are installing a SAS/SATA hot swap backplane with expander: Warning: SATA controllers cannot be used with an expander backplane. i. Connect the two power cables (see letter “A” in the following figure) to the power cable connectors on the SAS/SATA backplane. ii. Connect an SAS/SATA data cable (see letter “B”) to each appropriate SAS/ SATA connector on the SAS/SATA backplane. iii. Connect the IPMB cable (see letter “C”). iv.
Hot Swap Drive Cage Upgrade Install Instructions (optional) Installing a Hot Swap Hard Drive Note: The following set of instructions is only applicable if you replaced the fixed hard drive cage that shipped with your chassis with a SAS/SATA hard drive cage. If you are replacing a fixed hard drive, see “Removing a Fixed Hard Drive” for instructions. Note: The Intel® Server Chassis SC5650 does not support all hard drives.
Hot Swap Drive Cage Upgrade Install Instructions (optional) 2. Remove a drive carrier from the hot swap drive cage. Press in on the green latch (see letter “A” in the following figure) at the end of the drive carrier to disengage the drive carrier from the drive cage. Pull out on the black lever (see letter “B”) to push the drive carrier partially out of the drive cage. Slide the drive carrier all the way out of the drive cage. A B AF000312 Figure 91. Releasing Drive Carrier from Hot Swap Drive Cage 3.
Hot Swap Drive Cage Upgrade Install Instructions (optional) 7. Align the holes in the drive to the holes in the drive carrier and attach the drive to the carrier with the screws that were formerly attached to the plastic retention device. TP00929 Figure 93. Installing Hard Drive into Drive Carrier 8. With the black lever in the fully open position, insert the drive carrier into the hot swap drive cage. The green latch at the front of the drive carrier must be to the left of the drive cage.
Hot Swap Drive Cage Upgrade Install Instructions (optional) 9. Close the drive bay access door. AF000314 Figure 95. Closing Drive Bay Access Door Removing a Hot-swap Hard Drive 1. Open the drive bay access door. AF000311 Figure 96.
Hot Swap Drive Cage Upgrade Install Instructions (optional) 2. Press in on the green latch at the front of the drive carrier (see letter “A” in the following figure). Pull out on the black lever (see letter “B”) to slide the drive carrier from the hot swap drive cage. A B AF000312 Figure 97. Removing Drive Carrier from Hot Swap Drive Cage 3. Remove the four screws that attach the hard drive to the drive carrier. Lift the drive from the carrier. Store the old drive in an anti-static bag.
Hot Swap Drive Cage Upgrade Install Instructions (optional) 4. Remove the new drive from its anti-static bag and place in the drive carrier. With the drive circuit-side down, position the connector end of the drive so it is facing the rear of the drive carrier. Align the holes in the drive to the holes in the drive carrier and attach the drive to the carrier with the screws removed in the previous step.
Hot Swap Drive Cage Upgrade Install Instructions (optional) Note: For proper airflow, the drive carrier must be replaced in the chassis, even if no hard drive is installed in it. AF000313 Figure 101. Re-installing Drive Carrier in Hot Swap Drive Cage 6. Close the drive bay access door. AF000314 Figure 102.
Hot Swap Drive Cage Upgrade Install Instructions (optional) 82 Intel® Server Chassis SC5650-DP/WS/BRP/UP Service Guide
4 Rack Mount Kit Install Instructions (optional) The Intel® Server Chassis SC5650 can be configured as a rack-mount chassis when outfitted with the optional rack mount accessory kit. Before You Begin Before working with your server product, review the important safety information listed in Appendix A, “Safety Information”.
Rack Mount Kit Install Instructions (optional) 4. If installed, remove the chassis feet. Remove the pin from the rubber foot (see letter “A” in the following figure). Remove the rubber foot from the chassis hole (see letter “B”). Repeat process for remaining feet. A B TP01710 Figure 103. Removing Chassis Feet 5. Remove the top side cover by pressing the latch and pushing back on the side cover to slide rearward and lift from chassis. TP00958 Figure 104.
Rack Mount Kit Install Instructions (optional) 6. Remove any PCI add-in boards. Remove the PCI card guide by pressing in on the blue tabs (see letter “A” in the following figure) and pulling the PCI card guide outward (see letter “B”). A B TP02001 Figure 105.
Rack Mount Kit Install Instructions (optional) 7. Remove plastic filler panel from chassis by pushing on interior tab (see letter “A” in the following figure) and sliding filler panel towards rear of chassis (see letter “B”). B A AF000285 Figure 106.
Rack Mount Kit Install Instructions (optional) 8. Remove the three plastic plugs from the left side of chassis. AF000286 Figure 107. Removing Plastic Plugs (DP/WS/BRP configuration shown) 9. Remove two screws from the left and right sides of chassis. AF000287 Figure 108.
Rack Mount Kit Install Instructions (optional) 10. Remove the four plastic plugs from the top side cover. TP02004 Figure 109. Removing Plastic Plugs from Top Side Cover 11. Install rack handle on left side cover using four 6-32 screws. TP01053 Figure 110.
Rack Mount Kit Install Instructions (optional) 12. If removed, install front bezel assembly. Affix front panel label (see letter “A” in the following figure) to the front panel. A TP02005 Figure 111. Affixing Label to Front Panel 13. Install top side cover on chassis. Warning: This chassis must be operated with the left side cover installed to ensure proper cooling. TP01057 Figure 112.
Rack Mount Kit Install Instructions (optional) 14. Detach inner rack rail from rack rail assembly. Press tab on inside of rack rail to release rack rail from rack rail assembly. TP02006 Figure 113.
Rack Mount Kit Install Instructions (optional) 15. Attach inner rack rails (one per side) to chassis with four 6-32 screws. AF000288 Figure 114. Attaching Inner Rack Rails to Chassis (DP/WS/BRP configuration shown) 16. Attach outer rack rails to rack uprights. Ensure the screws (two per outer rack rail; see letter “A” in the following figure) pass through the rack upright (see letter “B”), and the outer rack rail (see letter “C”).
Rack Mount Kit Install Instructions (optional) C A B TP01056 Figure 115.
Rack Mount Kit Install Instructions (optional) 17. Install chassis into rack. Warning: Safe handling and lifting of this system requires TWO people. WARNING: Safe handling of this system requires TWO people. TP01058 Figure 116. Installing Chassis into Rack 18. Reconnect all peripheral devices and the AC power cable to the server. Power up the server.
Rack Mount Kit Install Instructions (optional) 94 Intel® Server Chassis SC5650-DP/WS/BRP/UP Service Guide
5 Technical Reference Cable Routing When you add or remove components from your server chassis, make sure your cables are routed correctly before reinstalling the chassis cover. Use caution to make sure no cables or wires are pinched and that the airflow from the fans is not blocked. Power Supply Specifications The power supply specifications for your Intel® Server Chassis SC5650 depend upon the configuration of chassis you purchased.
Technical Reference 600-W Single Power Supply Input Voltages • 100-127V at 50/60 Hz; 140 Vrms max. • 200-240V at 50/60 Hz; 264 Vrms max. 600-W Single Power Supply Output Current The following table lists the total amperage available from the power subsystem for each voltage. Ensure that your loads do not exceed the combined total wattage of 600 Watts. Table 5. 600-W Power Supply Output Capability Voltage Maximum Current +5 V Standby 3A +12.
Technical Reference DP 400-W Power Supply Output Voltages The following table lists the total wattage available from the power subsystem for each voltage. Ensure your loads do not exceed the combined total wattage of 400 W. For information about calculating the power usage for your configuration, see "Calculating Power Usage." Table 7. DP 400-W Power Supply Output Capability Voltage Maximum Current +3.3 V 20 A +5.0 V 20 A +5 V Standby 2.5 A +12.0 V1 16 A +12.0 V2 16 A -12.0 V 0.
Technical Reference 98 Intel® Server Chassis SC5650-DP/WS/BRP/UP Service Guide
A Safety Information English Server Safety Information This document applies to Intel® server boards, Intel® server chassis and installed peripherals. To reduce the risk of bodily injury, electrical shock, fire, and equipment damage, read this document and observe all warnings and precautions in this guide before installing or maintaining your Intel® server product.
Indicates hot components or surfaces. Indicates do not touch fan blades, may result in injury. Indicates to unplug all AC power cord(s) to disconnect AC power Please recycle battery Intended Application Uses This product was evaluated as Information Technology Equipment (ITE), which may be installed in offices, schools, computer rooms, and similar commercial type locations.
• Use mechanical assistance or other suitable assistance when moving and lifting equipment. • To reduce the weight for easier handling, remove any easily detachable components. Power and Electrical Warnings Caution: The power button, indicated by the stand-by power marking, DOES NOT completely turn off the compute module AC power, 5V standby power is active whenever the compute module is plugged in. To remove power from compute module, you must unplug the AC power cord from the wall outlet.
• When replacing a hot-plug power supply, unplug the power cord to the power supply being replaced before removing the power supply from the chassis. Caution: If the compute module has been running, any installed processor(s) and heat sink(s) may be hot. Unless you are adding or removing a hot-plug component, allow the compute module to cool before opening the covers.
Laser Peripherals or Devices Caution: To avoid risk of radiation exposure and/or personal injury: • Do not open the enclosure of any laser peripheral or device • Laser peripherals or devices have are not user serviceable • Return to manufacturer for servicing Deutsch Sicherheitshinweise für den Server Das vorliegende Dokument bezieht sich auf Intel® Serverplatinen, Intel® Servergehäuse (Standfuß und Rack) sowie installierte Peripheriegeräte.
Weist auf potentielle Gefahr bei Nichtbeachtung der angezeigten Informationen hin. Weist auf die Gefahr eines Stromschlags hin, der bei Nichtbeachtung der Sicherheitshinweise zu schweren oder tödlichen Verletzungen führen kann. Weist auf Verbrennungsgefahr an heißen Bauteilen bzw. Oberflächen hin. Weist darauf hin, daß das Anfassen des Gebläses zu Verletzungen führen kann. Bedeutet, alle Netzkabel abzuziehen und das Gerät von der Netzspannung zu trennen.
Handhabung von Geräten Beachten Sie zur Vermeidung von Verletzungen oder Beschädigungen an den Geräten die folgenden Hinweise: • Halten Sie beim Transportieren und Anheben von Geräten die örtlichen Gesundheitsund Sicherheitsvorschriften ein. • Verwenden Sie mechanische oder andere geeignete Hilfsmittel zum Transportieren oder Anheben von Geräten. • Entfernen Sie alle Komponenten, die sich leicht abnehmen lassen, um das Gewicht zu reduzieren und die Handhabung zu erleichtern.
Warnungen zu Netzspannung und Elektrizität Vorsicht: Durch Betätigen der mit dem Standby-Symbol gekennzeichneten Netztaste wird das System NICHT vollständig vom Netz getrennt. Es sind weiterhin 5 V aktiv, solange das System eingesteckt ist. Um das System vollständig vom Strom zu trennen, muß das Netzkabel aus der Steckdose abgezogen werden. Das System verfügt möglicherweise über mehrere Netzkabel. Vergewissern Sie sich in diesem Fall, daß alle Netzkabel abgezogen sind.
• Wenn Sie ein hot-plug-fähiges Netzteil austauschen, ziehen Sie dessen Netzkabel ab, bevor Sie es aus dem Server ausbauen. Vorsicht: War Ihr Server in Betrieb, können die installierten Prozessoren und Kühlkörper heiß sein. Sofern Sie keine Hot-Plug-Komponenten ein- oder ausbauen, warten Sie mit dem Abnehmen der Abdeckungen, bis das System abgekühlt ist. Gehen Sie beim Aus- oder Einbauen von Hot-Plug-Komponenten sorgfältig vor, um nicht mit heißen Komponenten in Berührung zu kommen.
Andere Gefahren Batterieaustausch Vorsicht: Wird die Batterie unsachgemäß ausgetauscht, besteht Explosionsgefahr. Verwenden Sie als Ersatz nur die vom Gerätehersteller empfohlene Batterie. Beachten Sie bei der Entsorgung von Batterien die gültigen Bestimmungen. Versuchen Sie nicht, eine Batterie aufzuladen. Versuchen Sie nicht, eine Batterie zu öffnen oder sonstwie zu beschädigen.
Français Consignes de sécurité sur le serveur Ce document s’applique aux cartes serveur Intel®, au châssis de serveur Intel® (sur pieds et sur rack) et aux périphériques installés. Pour réduire les risques de dommages corporels, d’électrocution, d’incendie et de dommages matériels, lisez ce document et respectez tous les avertissements et précautions mentionnés dans ce guide avant d’installer ou de mettre à jour votre produit serveur Intel®.
Indique de débrancher tous les cordons d’alimentation secteur pour déconnecter l’alimentation. Veuillez réutiliser la batterie Domaines d’utilisation prévus Ce produit a été testé comme équipement informatique (ITE) et peut être installé dans des bureaux, des écoles, des salles informatiques et des endroits commerciaux similaires.
Alimentation et avertissements en matière d’électricité Attention: Le bouton d’alimentation, indiqué par le symbole de mise en veille, NE COUPE PAS complètement l’alimentation secteur du système car le courant de veille 5 V reste actif lorsque le système est sous tension. Pour couper l’alimentation du système, vous devez débrancher le cordon d’alimentation secteur de la prise murale. Votre système peut utiliser plusieurs cordons d’alimentation secteur.
Attention: Si le serveur a été utilisé, les processeurs et dissipateurs de chaleur installés peuvent être chauds. À moins que vous n’ajoutiez ou ne retiriez un composant connectable à chaud, laissez le système refroidir avant d’ouvrir les panneaux. Pour éviter tout risque d’entrer en contact avec un composant chaud lors d’une installation à chaud, prenez toutes les précautions nécessaires lorsque vous retirez ou installez des composants connectables à chaud.
• Vérifiez tout d’abord que vous n’avez pas oublié d’outils ou de composants détachés à l’intérieur du système. • Vérifiez que les câbles, les cartes d’extension et les autres composants sont correctement installés. • Fixez les panneaux au châssis en suivant les instructions du produit. Périphériques laser Attention: Pour éviter tout risque d’exposition aux rayonnements et/ou de dommage personnel: • N’ouvrez pas l’enceinte d’un périphérique laser.
PRECAUCIÓN ADVERTENCIA Indica la existencia de un riesgo que podría causar lesiones personales o daños en la propiedad leves si no se tiene en cuenta la PRECAUCIÓN. Indica la existencia de un riesgo que podría causar lesiones personales graves si no se tiene en cuenta la ADVERTENCIA. Indica un riesgo potencial si no se tiene en cuenta la información indicada. Indica riesgo de descargas eléctricas que podrían causar lesiones graves o la muerte si no se siguen las instrucciones de seguridad.
• En zonas propensas a tormentas eléctricas, se recomienda que conecte el servidor a un supresor de sobretensiones y desconecte las líneas de telecomunicaciones al módem durante una tormenta eléctrica. • Provista de una toma de corriente alterna correctamente conectada a tierra. • Provista de espacio suficiente para acceder a los cables de la fuente de alimentación ya que constituyen la desconexión principal de la alimentación.
puede haber niveles de tensión, corriente y energía peligrosos. Devuélvala al fabricante para repararla. Al reemplazar una fuente de alimentación de conexión en funcionamiento, desenchufe el cable de alimentación de la fuente de alimentación que va a reemplazar antes de extraerla del servidor. Para evitar el riesgo de descargas eléctricas, antes de abrir el servidor, apáguelo, desconecte el cable de alimentación, los sistemas de telecomunicaciones, las redes y los módems conectados al mismo.
de conexión en funcionamiento, tenga cuidado al extraer o instalar los componentes de conexión en funcionamiento. Precaución: Para evitar posibles daños, no toque las aspas en movimiento de los ventiladores. Si el sistema se le ha suministrado con una protección para el ventilador, asegúrese de que cuando esté funcionando el sistema la protección esté en su sitio. Descarga electrostática (ESD) Precaución: Las descargas electrostáticas pueden dañar las unidades de disco, las tarjetas y otros componentes.
Periféricos o dispositivos láser Precaución: Para evitar el riesgo de la exposición a radiaciones o de daños personales: • No abra la caja de ningún periférico o dispositivo láser • Los periféricos o dispositivos láser no pueden ser reparados por el usuario • Haga que el fabricante los repare.
Intel® Server Chassis SC5650-DP/WS/BRP/UP Service Guide 119
120 Intel® Server Chassis SC5650-DP/WS/BRP/UP Service Guide
Intel® Server Chassis SC5650-DP/WS/BRP/UP Service Guide 121
122 Intel® Server Chassis SC5650-DP/WS/BRP/UP Service Guide
Intel® Server Chassis SC5650-DP/WS/BRP/UP Service Guide 123
124 Intel® Server Chassis SC5650-DP/WS/BRP/UP Service Guide
Appendix B: Installation/Assembly Safety Instructions English The power supply in this product contains no user-serviceable parts. There may be more than one supply in this product. Refer servicing only to qualified personnel. Do not attempt to modify or use the supplied AC power cord if it is not the exact type required. A product with more than one power supply will have a separate AC power cord for each supply. The power button on the system does not turn off system AC power.
After you have completed the six SAFETY steps above, you can remove the system covers. To do this: 1. Unlock and remove the padlock from the back of the system if a padlock has been installed. 2. Remove and save all screws from the covers. 3. Remove the cover(s). For proper cooling and airflow, always reinstall the chassis covers before turning on the system. Operating the system without the covers in place can damage system parts. To install the covers: 1.
Deutsch Benutzer können am Netzgerät dieses Produkts keine Reparaturen vornehmen. Das Produkt enthält möglicherweise mehrere Netzgeräte. Wartungsarbeiten müssen von qualifizierten Technikern ausgeführt werden. Versuchen Sie nicht, das mitgelieferte Netzkabel zu ändern oder zu verwenden, wenn es sich nicht genau um den erforderlichen Typ handelt. Ein Produkt mit mehreren Netzgeräten hat für jedes Netzgerät ein eigenes Netzkabel.
SICHERHEITSMASSNAHMEN: Immer wenn Sie die Gehäuseabdeckung abnehmen um an das Systeminnere zu gelangen, sollten Sie folgende Schritte beachten: 1. Schalten Sie alle an Ihr System angeschlossenen Peripheriegeräte aus. 2. Schalten Sie das System mit dem Hauptschalter aus. 3. Ziehen Sie den Stromanschlußstecker Ihres Systems aus der Steckdose. 4. Auf der Rückseite des Systems beschriften und ziehen Sie alle Anschlußkabel von den I/O Anschlüssen oder Ports ab. 5.
Das System wurde für den Betrieb in einer normalen Büroumgebung entwickelt.
CONSIGNES DE SÉCURITÉ -Lorsque vous ouvrez le boîtier pour accéder à l'intérieur du système, suivez les consignes suivantes: 1. Mettez hors tension tous les périphériques connectés au système. 2. Mettez le système hors tension en mettant l'interrupteur général en position OFF (bouton-poussoir). 3. Débranchez tous les cordons d'alimentation c.a. du système et des prises murales. 4. Identifiez et débranchez tous les câbles reliés aux connecteurs d'E-S ou aux accès derrière le système. 5.
Danger d'explosion si la batterie n'est pas remontée correctement. Remplacer uniquement avec une batterie du même type ou d'un type équivalent recommandé par le fabricant. Disposez des piles usées selon les instructions du fabricant. Le système a été conçu pour fonctionner dans un cadre de travail normal. L'emplacement choisi doit être: • "Propre et dépourvu de poussière en suspension (sauf la poussière normale). • "Bien aéré et loin des sources de chaleur, y compris du soleil direct.
Nótese que el interruptor activado/desactivado en el panel frontal no desconecta la corriente alterna del sistema. Para desconectarla, deberá desenchufar todos los cables de corriente alterna de la pared o desconectar la fuente de alimentación. Estos cables actúan como dispositivo de desconexión. La toma de corriente deberá estar situada cerca del equipo y ser de fácil acceso.
Si el sistema ha estado en funcionamiento, el microprocesador y el disipador de calor pueden estar aún calientes. También conviene tener en cuenta que en el chasis o en el tablero puede haber piezas cortantes o punzantes. Por ello, se recomienda precaución y el uso de guantes protectores. Existe peligro de explosión si la pila no se cambia de forma adecuada. Utilice solamente pilas iguales o del mismo tipo que las recomendadas por el fabricante del equipo.
Non modificare o utilizzare il cavo di alimentazione in c.a. fornito dal produttore, se non corrisponde esattamente al tipo richiesto. Ad ogni fonte di alimentazione corrisponde un cavo di alimentazione in c.a. separato L'interruttore attivato/disattivato nel pannello anteriore non interrompe l'alimentazione in c.a. del sistema. Per interromperla, è necessario scollegare tutti i cavi di alimentazione in c.a. dalle prese a muro o dall'alimentazione di corrente.
Se il sistema è stato a lungo in funzione, il microprocessore e il dissipatore di calore potrebbero essere surriscaldati. Fare attenzione alla presenza di piedini appuntiti e parti taglienti sulle schede e sul telaio. È consigliabile l'uso di guanti di protezione. Esiste il pericolo di un esplosione se la pila non viene sostituita in modo corretto. Utilizzare solo pile uguali o di tipo equivalente a quelle consigliate dal produttore. Per disfarsi delle pile usate, seguire le istruzioni del produttore.
136 Intel® Server Chassis SC5650-DP/WS/BRP/UP Service Guide
Appendix C:Getting Help Getting Help If you encounter an issue with your server system, follow these steps to obtain support: 1. Visit the following Intel support web page: http://support.intel.com/support/motherboards/server This web page provides 24x7 support when you need it to get the latest and most complete technical support information on all Intel Enterprise Server and Storage Platforms.
Getting Help 138 Intel® Server Chassis SC5650-DP/WS/BRP/UP Service Guide
Appendix D:Intel® Server Chassis Issue Report Form Note: An on-line / automatic submission version of this form is available at http:// support.intel.com/support/motherboards/server/chassis/sc5650/. For the fastest service, please submit your form via the Internet.
Intel® Server Chassis Issue Report Form DIMM Configuration DIMM1A MB and Vendor / part number: __________________________________ DIMM1B MB and Vendor / part number: __________________________________ DIMM2A MB and Vendor / part number: __________________________________ DIMM2B MB and Vendor / part number: __________________________________ DIMM3A MB and Vendor / part number: __________________________________ DIMM3B MB and Vendor / part number: __________________________________ DIMM4A MB and Vendor / par
Intel® Server Chassis Issue Report Form X Peripheral Description Driver Revision IRQ I/O Base Address Make/Model Hot-swap or Fixed IRQ FW Revision FW Revision On-board NIC2 Hard Drive Information X Drive Type (SAS, SATA, etc.
Intel® Server Chassis Issue Report Form Complete Problem Description In the space below, provide a complete description of the steps used to reproduce the problem or a complete description of where the problem can be found. Please also include any details on troubleshooting already done.
Appendix E:Warranty Limited Warranty for Intel® Chassis Subassembly Products Intel warrants that the Products (defined herein as the Intel® chassis subassembly and all of its various components and software delivered with or as part of the Products) to be delivered hereunder, if properly used and installed, will be free from defects in material and workmanship and will substantially conform to Intel's publicly available specifications for a period of three (3) years after the date the Product was purchased
Warranty Warranty Limitations and Exclusions These warranties replace all other warranties, expressed or implied including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Intel makes no expressed warranties beyond those stated here. Intel disclaims all other warranties, expressed or implied including, without limitation, implied warranties of merchantability and fitness for a particular purpose.
Warranty Any replacement Product is warranted under this written warranty and is subject to the same limitations and exclusions for the remainder of the original warranty period. Telephone Support If you cannot find the information you need on Intel's World Wide Web site (http:// www.intel.com/), call your local distributor or an Intel Customer Support representative. See “Getting Help” for telephone numbers.
Warranty 146 Intel® Server Chassis SC5650-DP/WS/BRP/UP Service Guide
Appendix F: Regulatory and Compliance Information Product Regulatory Compliance Warning: To ensure regulatory compliance, you must adhere to the assembly instructions in this guide to ensure and maintain compliance with existing product certifications and approvals. Use only the described, regulated components specified in this guide.
• CB Certificate & Report, IEC60950 (report to include all country national deviations) • GS License (Germany) • • • • • GOST R 50377-92 - License (Russia) Belarus License (Belarus) Ukraine License (Ukraine) CE - Low Voltage Directive 73/23/EEE (Europe) IRAM Certification (Argentina) Product EMC Compliance - Class A Compliance This server system has been tested and verified to comply with the following electromagnetic compatibility (EMC) regulations when installed in a compatible Intel® host system.
Certifications / Registrations / Declarations • • • • • • • • • • • • UL Certification (US/Canada) CE Declaration of Conformity (CENELEC Europe) FCC/ICES-003 Class A Attestation (USA/Canada) VCCI Certification (Japan) C-Tick Declaration of Conformity (Australia) MED Declaration of Conformity (New Zealand) BSMI Certification (Taiwan) GOST R Certification / License (Russia) Belarus Certification / License (Belarus) RRL Certification (Korea) IRAM Certification (Argentina) Ecology Declaration (International)
Table 9.
Electromagnetic Compatibility Notices FCC Verification Statement (USA) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. For questions related to the EMC performance of this product, contact: Intel Corporation 5200 N.E.
Industry Canada (ICES-003) Cet appareil numérique respecte les limites bruits radioélectriques applicables aux appareils numériques de Classe A prescrites dans la norme sur le matériel brouilleur: "Apparelis Numériques", NMB-003 édictee par le Ministre Canadian des Communications.
Korean Compliance (RRL) Following is the RRL certification information for Korea. English translation of the notice above: 1. Type of Equipment (Model Name): On License and Product 2. Certification No.: On RRL certificate. Obtain certificate from local Intel representative 3. Name of Certification Recipient: Intel Corporation 4. Date of Manufacturer: Refer to date code on product 5.
Restriction of Hazardous Substances (RoHS) Compliance Intel has a system in place to restrict the use of banned substances in accordance with the European Directive 2002/95/EC. Compliance is based on declaration that materials banned in the RoHS Directive are either (1) below all applicable substance threshold limits or (2) an approved/pending RoHS exemption applies. Note: RoHS implementation details are not fully defined and may change. Threshold limits and banned substances are noted below.