Technical Product Specification

System Cooling Intel® Server Chassis SC5600
Revision 1.1
Intel order number E39532-004
24
4.5 Fan Header Connector Descriptions
All system fan headers support pulse width modulated (PWM) fans for cooling the processors in
the chassis. PWM fans have an improved RPM range (20% to 100% rated fan speed) when
compared to voltage controlled fans.
Base and BRP chassis fans are a 4-wire/4-pin style designed to plug into 4-pin or 6-pin SSI Fan
headers. When plugged into a 6-pin header, only the first four signals are used (Pwr, Gnd, Tach,
PWM).
LX chassis fans are a 6-wire/6-pin style designed to plug into 6-pin headers. The extra signals
provide for fan redundancy and failure indications (Pwr, Gnd, Tach, PWM, Presence, and
Failure).
Server Boards installed in this chassis may feature two additional 4-pin CPU fan headers and
one additional 4-pin system fan headers. These connections are not required for use with the
Intel
®
Server Chassis SC5600.
To assist with fan connections in the system, the system fans are numbered one through five
and color-coded. These correspond to fan header numbers on the server board. Fan 1 and fan
2 connectors are white in color and the fan 3, fan 4, and fan 5 connectors are blue in color.
These colors should also match between server board and fans.