Technical Product Specification
Intel® Server Chassis SC5600 Hot-swap Hard Disk Drive Bays
Revision 1.1
Intel order number E39532-004
51
The passive backplane acts as a “pass-through” for the SAS/SATA data from the drives to the
SAS/SATA controller on the baseboard or a SAS/SATA controller add-in card. It provides the
physical requirements for the hot-swap capabilities.
The active backplane has a built-in SAS expander controller that requires a SAS controller on
the baseboard or a SAS add-in card for communication. The Active SAS/SATA backplane
reduces the number of required cables by only using two SAS/SATA connectors to drive up to
six hard drives.
When the hot-swap drive bay is installed, a bi-color hard drive LED located on each drive carrier
indicates specific drive failure or activity. For pedestal systems, these LEDs are visible when the
front bezel door is open.
6.1 Intel
®
Server Chassis SC5600 4HDD and 6HDD Passive SAS/SATA Hot-
swap Back Plane (HSBP) Overview
The Intel
®
Server Chassis SC5600 4-drive or 6-drive Passive SAS/SATA hot-swap Backplane
(HSBP) is a monolithic printed circuit board (PCB). The architecture is based on the Vitesse
Server Board and storage management controller VSC410* and supports up to four or six
SAS/SATA drives.
The 4HDD and 6HDD SAS/SATA HSBP supports the following feature set:
Vitesse Server Board and storage management controller VSC410*
Serial Flash memory
I
2
C EEPROM
Temperature Sensor
Four I
2
C interfaces
One SGPIO Interface
Compliance with SCSI Accessed Fault Tolerant Enclosures (SAF-TE) specification,
version 1.00 and addendum
Compliance with SCSI Enclosure Service (SES) specification.
Compliance with Intelligent Platform Management Interface (IPMI) 1.5.
Support for up to four or six SAS1.5/3.0Gbps, SATA I or SATA II Drives
Hot-swap Drive support
Two 4-pin Standard HD Power Connectors