Technical Product Specification

System Cooling Intel® Server Chassis SC5600
Revision 1.1
Intel order number E39532-004
22
4.3 Redundant Cooling Solution
Redundant cooling solution is used in the Intel
®
Server Chassis SC5600LX.
Two hot-swap 120x38 mm fans and two hot-swap 92x38 mm fans provide cooling for the
processors, hard drives, and add-in cards. The two 120x38 mm fans ensure proper cooling of
the core area (processors and memory) and the hot-swap drive bay. The two 92x38 mm fans
provide cooling for the PCI card area. When any single fan fails, the remaining fans increase in
speed and maintain cooling until the failed unit is replaced. All system fans provide a signal for
RPM detection that the server board can make available for server management functions.
In addition, the power supply fan provides cooling for the power supply.
Figure 17. Hot-swap Fans and Connectors