Service Guide

Technical Reference
58 Intel®
Server Chassis SC5600 Service Guide
Table 6. 750-W Hot Swap Power Supply Output Capability
Voltage Maximum Current
+ 3.3 V 24 A
+5 V 30 A
+12 V1 24 A
+12 V2 24 A
+12 V3 16 A
+12 V4 16 A
-12 V 0.5 A
+5 VSB 3.0 A
WARNING
Do not exceed a combined power output of 170 W for the +5 V and +3.3 V outputs. Exceeding a
combined 170 W will overload the power subsystem and may cause the power supplies to overheat
and malfunction.
The expansion slots on the server board are rated for no more than 25 W for any one slot. The
average current usage per slot should not exceed 13 W.
System Environmental Specification
Table 7. Environmental Specification
Temperature
Non-operating: -40 ° to 70 °C
Operating: 10 ° to 35 °C; derated 0.5 °C for every 1000 ft. (305 m) to a maximum of
10,000 feet
Humidity
Non-operating: 90% relative humidity (non-condensing) at 30 °C.
Shock
Operating: 2.0 g, 11 msec, 1/2 sine
Packaged: Operational after an 18-inch free fall.
Acoustic Noise
Base, BRP, and LX configurations - 5.8 BA LWA idle; 6.0 BA LWA typical operating
Electrostatic Discharge
(ESD)
Tested to 15 kilovolts (kV); no component damage