Technical Product Specification
Chassis Power Subsystem IntelĀ® Server Chassis SC5400 5U Kit TPS
42 Revision: 1.0
5.3.2 Temperature Operational Limits
The power supply modules provide airflow to cool the power distribution board. The power
distribution board operates over the specified limits listed in the following table:
Table 27. Thermal Requirements
Item Description Minimum Maximum Units
T
op
Operating temperature range. 10 45 C
T
non-op
Non-operating temperature range. -40 70 C
5.3.3 Electrical Specification
5.3.3.1 Input Connectors
Each connector provides card edge fingers, which mate with the female input connector on the
power distribution board. The female type connector on the power distribution board is a right
angle 2x31 pin type Singatron* (p/n: 2806-62-R-30T-P-K1) or equivalent.
Signals that are defined as low true or high true use the following convention:
signal# = low true
Reserved pins are reserved for future use.
Table 28. Cable Lengths
From
Length For Revision S0
Only (mm)
Connector
#
Number of
Pins
Description
Power supply cover exit hole 450 P1 24
Server Board Power
Connector
Power supply cover exit hole 755 P2 8
Processor Power
Connector
Power supply cover exit hole 230 P3 4
Peripheral Power
Connector
Extension 100 P4 4
Peripheral Power
Connector
Extension 100 P5 4
Floppy
1
Power Connector
Power supply cover exit hole 540 P6 4
Peripheral Power
Connector
Extension 75 (cover with sleeve) P7 4
Right-angle Peripheral
Power Connector
Power supply cover exit hole
565
P8 4
Peripheral Power
Connector
Extension
75
P9 4
Peripheral Power
Connector