User's Guide
Table Of Contents
- About this Manual
- Manual Organization
- Intel® Serverboard Compatibility
- Additional Information and Software
- Safety Information
- Warnings
- Chassis Description
- Setting Up the Chassis
- Tools and Supplies Needed
- Installation Safety Instructions
- Remove Primary Access Cover
- Remove Bezel Assembly
- Remove Air Ducts
- Remove Hot Swap Fans
- Route Power and Data Cables to the Fixed Drives
- Install 3.5-inch Floppy Drive
- Install DVD or CD-ROM Drive.
- Install Fixed Hard Drive(s)
- Install Hot Swap Drive(s)
- Install Hot Swap Fans
- Install Server Board
- Install Air Dam
- Connect Cables to Server Board
- Install Add-in Board(s)
- Install Air Ducts
- Install an Additional Hot Swap Power Supply Module
- Install Bezel Assembly (Pedestal Only)
- Install Primary Access Cover
- Maintaining Your Server
- Tools and Supplies Needed
- Safety: Before You Remove the Access Cover(s)
- Warnings and Cautions
- Replacing a Fixed Fan (For Base and BRP Chassis Only)
- Replacing a Hot Swap Fan
- Replacing the Front Panel Board
- Replacing a Fixed Power Supply
- Replacing a Hot Swap Power Supply
- Replacing a Power Distribution Board
- Upgrading from a Fixed Power Supply to a Hot Swap Power Supply
- Technical Reference
- Equipment Log and Worksheets
- Regulatory and Compliance Information
- Getting Help
- Warranty

Chassis Description
Intel® Server Chassis SC5300 User Guide 5
Descriptions of the front panel LEDs are listed in the following table. Refer to your server
documentation for functionality of buttons.
Table 2. Front Panel LED Descriptions
LED Name Color Condition Description
Green ON Power on
Green BLINK Standby/Sleep (S1)
Power/Sleep LED
OFF Off (also Sleep S4)
Green ON System ready
Green BLINK System ready, but degraded: some CPU fault, DIMM killed
Amber ON
Critical alarm: Critical power module failure, critical fan failure,
voltage (power supply), voltage and thermal fault
Amber BLINK
Non-critical failure: Redundant fan failure, redundant power
failure, non-critical power and voltage
Status
OFF
System not ready: Post error/NMI event/PCI or terminator
missing
Green BLINK Hard drive activity
Amber ON Fault
Hard drive activity
OFF No activity
Green ON Linked
Green BLINK LAN activity
NIC1 activity
OFF Idle
Green ON Linked
Green BLINK LAN activity
NIC2 activity
OFF Idle
Blue BLINK Server identification; Toggled by ID button or software
ID LED
2
(rack only)
OFF Server identification; Toggled by ID button or software
2
Not supported by all server boards.