White Paper - Intel Intelligent Power Node Manager
Intel® Server
Chassis
Chassis-specific Server Management
Features
Chassis-dependent Sensors Managed by
Management Controller
Intel Policy-Based
Node Manager
Support
SC5600BASE • Non- redundant power:
One
power supply module which
is not manageable
• Non-redundant cooling: Five
fixed chassis fans which
are not hot swappable
• Chassis Intrusion
• Five fan tachometer sensors
• Two fan presence sensors
• One front panel temperature sensor
• One physical security sensor: Chassis
intrusion offset
No
SC5600BRP • Redundant power: Two
PMBus enabled power
supply modules which are
manageable
• Power Distribution Board
(PDB)
• Non-redundant cooling: Five
fixed chassis fans which
are not hot swappable
• Chassis Intrusion
• Five fan tachometer sensors
• Two fan presence sensors
• One front panel temperature sensor
• PMBus sensors
• Two input power sensors
• Two output current sensors
• Two power supply temperature
sensors
• Two power supply status sensors
• PDB failure monitoring reflected in the
power unit sensor ‘failure’ offset
• One physical security sensor: Chassis
intrusion offset
Yes
SC5600LX • Redundant power: Two
PMBus enabled power
supply modules which are
manageable
• Power Distribution Board
(PDB)
• Redundant cooling: Four
hot swappable chassis fans
• Chassis Intrusion
• Four fan tachometer sensors
• Four fan presence sensors
• One front panel temperature sensor
• PMBus sensors
• Two input power sensors
• Two output current sensors
• Two power supply temperature
sensors
• Two power supply status sensors
• PDB failure monitoring reflected in the
power unit sensor ‘failure’ offset
• One physical security sensor: Chassis
intrusion offset
Yes
SC5650BRP • Redundant power: Two
PMBus enabled power
supply modules which are
manageable
• Power Distribution Board
(PDB)
• Non-redundant cooling: 5
fixed chassis fans which
are not hot swappable.
• Chassis intrusion
• Five fan tachometer sensors
• One front panel temperature sensor
• PMBus sensors
• Two input power sensors
• Two output current sensors
• Two power supply temperature
sensors
• Two power supply status sensors
• PDB failure monitoring reflected in the
power unit sensor ‘failure’ offset
• One power unit redundancy sensor
• One physical security sensor: Chassis
intrusion offset
Yes
Table 1 List of Chassis with hardware combination