White Paper - Intel Intelligent Power Node Manager
3. Intel® 5500 series chipset systems and their hardware support
needed for Node Manager
Intel® Server
Chassis
Chassis-specific Server Management
Features
Chassis-dependent Sensors Managed by
Management Controller
Intel Policy-Based
Node Manager
Support
SR1600UR • Non- redundant power: One
power supply module that
is not manageable
• Non-redundant cooling: Ten
fixed chassis fans which
are not hot swappable
• Ten fan tachometer sensors
• One front panel temperature sensor
No
SR1625UR • Redundant power: Two
PMBus enabled power
supply modules which are
manageable
• Power Distribution Board
(PDB)
• Non-redundant cooling: Ten
fixed chassis fans which
are not hot swappable
• Ten fan tachometer sensors
• One front panel temperature sensor
• PMBus sensors
• Two input power sensors
• Two output current sensors
• Two power supply temperature
sensors
• Two power supply status sensors
• PDB failure monitoring reflected in the
power unit sensor ‘failure’ offset
• One power unit redundancy sensor
Yes
SR1630BC • Non-redundant power: One
power supply module which
is not manageable
• Non-redundant cooling:
Two fixed chassis fans
which are not hot
swappable
• Two fan tachometer sensors
• One front panel temperature sensor
No
SR2600URBRP • Redundant power: Two
PMBus enabled power
supply modules which are
manageable
• Power Distribution Board
(PDB)
• Non-redundant cooling:
Three fixed chassis fans
which are not hot
swappable
• Chassis Intrusion
• Three fan tachometer sensors
• One front panel temperature sensor
• PMBus sensors
• Two input power sensors
• Two output current sensors
• Two power supply temperature
sensors
• Two power supply status sensors
• PDB failure monitoring reflected in the
power unit sensor ‘failure’ offset
• One physical security sensor: Chassis
intrusion offset
Yes
SR2600URLX • Redundant power: Two
PMBus enabled power
supply modules which are
manageable
• Power Distribution Board
(PDB)
• Redundant cooling: Six hot
swappable chassis fans
• Chassis Intrusion
• Six fan tachometer sensors
• Six fan presence sensors
• One front panel temperature sensor
• PMBus sensors
• Two input power sensors
• Two output current sensors
• Two power supply temperature
sensors
• Two power supply status sensors
• PDB failure monitoring reflected in the
power unit sensor ‘failure’ offset
• One physical security sensor: Chassis
intrusion offset
Yes