Specification Update

Enterprise Platforms and Services Marketing Monthly Specification Update
vi
21. Firmware will detect a missing server board battery as present and good ............ 12
22. Server Board cannot detect a 10 Gb I/O Module or a Quad Data Rate InfiniBand*
I/O Module without a PCI Riser installed ................................................................................ 12
23. Cannot update DVD Drive Firmware when Six DIMMs are installed ..................... 13
24. Closed Loop Thermal Throttling (CLTT) is not automatically detected and set
when using unbuffered memory (UDIMMs) ............................................................................ 13
25. Failed power supply fans in Intel
®
Server System SR2600UR/SR2625UR may
cause continuous reboots ...................................................................................................... 14
26. Intel
®
Deployment Assistant (IDA) cannot be used to perform unattended Microsoft
Windows* OS installs............................................................................................................. 14
27. Excessive Time to Enter or Exit EFI Shell When AHCI is Enabled in BIOS
Revision R0037 ..................................................................................................................... 14
28. Fans may boost when Processor Therm Crtl % sensor is read repeatedly. .......... 15
29. Serial Over LAN (SOL) Will not Automatically Enable Console Redirection When
Console Redirection Is Disabled In BIOS Setup .................................................................... 15
30. Boot Order May Change After Entering RAID Setup ............................................ 15
31. LCP may not able to display correct reading of some negative temperature values16
32. SR2612UR Hard Disk Status LED is illuminated always ...................................... 16
33. A "USB to IDE/SATA" device appears in BIOS and OS when a SATA optical drive
is not installed in a SR1625UR, SR2600UR, or SR2625UR system. ..................................... 16
34. High CPU utilization may occur when installing or running Windows 2008 R2/
Windows 7 with default NIC driver ......................................................................................... 17
35. Clearing BIOS CMOS in BIOS Revision R0042 May Return an Invalid Date ........ 17
36. SLES11 kernel may halt during installation with default BIOS setting .................. 18
37. Intel(R) Active System Console (IASC) 3.5.1 and 3.5.2 may fail to detect status of
memory voltage sensors ........................................................................................................ 18
38. Inaccurate HSC FW revision displayed in BIOS Setup Page. .............................. 19
39. Lower network performance may be observed when Hyper-V role is added in
Windows Server 2008 R2 with more than 32G memory. ....................................................... 20
40. System with BIOS Revision R0054 may hang when Adaptec* 5405 or 5805 RAID
card installed. ........................................................................................................................ 20
41. System may go to EFI first instead of Hardware RAID configuration setup page. 20
42. System will generate a beep sound of 1-5-4-2 warning when the setting for the
Intel(R) VT-D or HT technology in BIOS is changed .............................................................. 21
43. System will get blue screen on display during the installation of Windows 2008 R2
under UEFI mode. ................................................................................................................. 21
44. User will read wrong Processor frequency in BIOS R0058. .................................. 21