Specification Update

Monthly Specification Update Enterprise Platforms and Services Marketing
15
Workaround None.
Tracker 189857
28. Fans may boost when Processor Therm Crtl % sensor is read
repeatedly.
Problem The system fans may boost when the processor Therm Crtl % sensor (Sensor
#64 & #65) is read at a high frequency, such as several times a second. The
Therm Ctrl % sensors will read as unavailable for subsequent sensor readings
until a system reset is performed.
Implication The systems fans will run at a higher state temporarily, increasing acoustics,
and processor temperature readings will be unavailable.
Status This issue is fixed in BMC 42.
Workaround None
29. Serial Over LAN (SOL) Will not Automatically Enable Console
Redirection When Console Redirection Is Disabled In BIOS Setup
Problem If console redirection is disabled in BIOS setup SOL will no longer
automatically detect this condition and then enable console redirection.
Implication Console redirection must be enabled in BIOS setup prior to utilizing
SOL. Furthermore, the IPMI command SetSystemBootOption to enable
console redirection is not supported.
Status This issue may be fixed in a future BIOS revision or with the optional IPMI
command support.
Workaround None.
30. Boot Order May Change After Entering RAID Setup
Problem: Boot Order May Change After Entering RAID Setup
Implication: The boot order may be changed after entering RAID configuration ROM (Ctrl+G).
The boot order will not be affected if the RAID configuration ROM (Ctrl+G) is
not entered.