25. Failed power supply fans in Intel
®
Server System
SR2600UR/SR2625UR may cause continuous reboots
Problem If a power supply fan fails in Intel
®
Server System SR2600UR and Intel
®
Server
System SR2625UR, the system may enter a continuous reboot cycle. If
redundant supplies are populated, the system will only reboot if fans in both
power supplies fail simultaneously.
Implication If a power supply fan fails, the system may enter a reboot cycle. This problem
will only occur in instances where a shutdown is expected. The system will
reboot rather than shutting down.
Status This issue may be fixed in a future version of the power supply.
Workaround None
Tracker 189641
26. Intel
®
Deployment Assistant (IDA) cannot be used to perform
unattended Microsoft Windows* OS installs
Problem The OCD.XML file included on the Resource CD is incorrect and prevents IDA
from properly installing RAID drivers when preparing for an unattended
installation.
Implication IDA cannot be used to prepare unattended installations of Microsoft Windows*
Operating Systems.
Status This issue may be fixed in a future revision of the Resource CD.
Workaround None
Tracker 189580
27. Excessive Time to Enter or Exit EFI Shell When AHCI is Enabled in BIOS
Revision R0037
Problem If AHCI is enabled in BIOS setup, it will take the user approximately 3 or more
minutes to enter the EFI shell from BIOS Setup and approximatley 3 or more
minutes to exit the EFI shell.
Implication Users should expect long delays when entering the EFI shell from BIOS setup
if AHCI is also enabled.
Status This issue may be fixed in a future BIOS revision.