Specification Update

Monthly Specification Update Enterprise Platforms and Services Marketing
11
17. Extra events may be seen in the SEL during system reset
Problem The BMC may log periodic, spurious SEL events during a system reset. These
events may appear as fan errors or duplicate instances of normal events. The
spurious fan readings will only happen during reset and are not an indication of
an actual fan failure. Fan failure events that occur during a reboot should be
ignored.
Implication The SEL log may indicate fan errors or duplicate instances of normal events
intermittently.
Status This issue may be fixed in a future BMC release.
Workaround None
Tracker 35068, 189715, 33970
18. BIOS setup may report an incorrect firmware version
Problem The BIOS setup screens that display the SDR and ME firmware versions may
report incorrect versions. The version displayed may be of the previously
installed version.
Implication After firmware update, the BIOS screens may not show the correct version until
the system is AC cycled.
Status This issue may be fixed in a future BMC release.
Workaround None.
Tracker 189678, 189455
19. Hard drive status LED for blank drive slots may blink amber when
system is in AHCI mode
Problem The hard drive status LEDs for empty drive slots may blink amber when the
system is operating in AHCI mode.
Implication The hard drive status LED may indicate a false status for an unpopulated drive
slot.
Status This issue is fixed in BIOS37 and BMC 38 and later.
Workaround None.