10
Problem When operating in the serial console mode, the user may notice one of the
following two conditions during POST:
The user may see the numeral 10 displayed at the top right corner of the
screen
OR
The RAID controller information may be intermingled with the platform
information displayed by BIOS.
Implication There is no functional impact associated with this erratum.
Status This may be fixed in a future BIOS revision.
Workaround None.
Tracker 189551
15. The PXE boot option is missing in the BIOS Setup
Problem If a user disables the primary (onboard) video in the BIOS Setup, the PXE boot
option will disapear from the BIOS Boot Manager.
Implication Users that desire to utilize the PXE boot option must leave the primary
(onboard) video enabled.
Status This issue may be fixed in a future BIOS revision.
Workaround None.
Tracker 35253
16. Fans may boost temporarily when BMC is under load
Problem The system fans may boost when the BMC is operating under a heavy load.
This can include large sequential BMC tasks such as viewing the system event
log, configuring the BMC or resetting the system. The fans return to normal
automatically after the BMC operations complete.
Implication The systems fans will run at a higher state temporarily, thereby increasing
acoustics.
Status This issue is fixed in BMC 36 and later.
Workaround None.
Tracker 189578, 189317