Specification Update

Enterprise Platforms and Services Marketing Monthly Specification Update
2
Summary Tables of Changes
The following tables provide an overview of known errata and known document changes that
apply to the specified Intel Server Products. The tables use the following notations:
Doc
Intel intends to update the appropriate documentation in a future revision.
Fix
Intel intends to correct this erratum.
Fixed
This erratum has been corrected.
NoFix
There are no plans to correct this erratum.
Shaded
This item is new or has been modified from the previous specification update.
Table 1. Errata Summary
No.
Plans
Description of Errata
1
Fixed
System will hang while accessing RAID BIOS setup screen with RAID Midplane in hardware mode
installed
2
Fix
Mixed PCI Express* (PCIe*) devices installed on the ASR26XXFHLPR riser full-height slots 1 and 2
may cause a system hang
3
Fixed
Cannot boot to SATA CD-ROM device with a SATA SW RAID enabled in conjunction with a 1064e
backplane installed
4
Fixed
Changing console redirection setting in BIOS setup may result in loss of information in the Boot
Manager page of BIOS setup
5
Fixed
BIOS recovery is not available using the on-board USB DVD/CD-ROM optical drive
6
Fixed
System may hang during POST if console redirection is set to 9600 baud
7
Fixed
POST messages do not correctly display when using console redirection over Serial Over LAN (SOL)
8
Fixed
False NMI being reported with certain versions of Linux operating system installations
9
Fix
Errors are reported during the installation of SuSE* Linux Enterprise Server 10 EM64T
10
Fixed
Hyper-Threading cannot be disabled in the BIOS setup
11
No Fix
A critical interrupt is logged in the System Event Log (SEL) when installing SuSE* Linux Enterprise
Server 10 32-bit
12
No Fix
Wake on LAN (WOL) does not work on 1GB I/O Modules
13
Fixed
The operating system may take more than four hours to install in SATA compatabiltiy mode
14
Fix
Serial Console mode may display extra text or intermingled text
15
Fix
The PXE boot option is missing in BIOS setup
16
Fixed
Fans may boost temporarily when the BMC is under load
17
Fix
Extra events may be seen in the SEL during system reset
18
Fixed
BIOS setup may report an incorrect firmware version
19
Fixed
Hard Drive status LED for blank drive slots may blink amber when system is in AHCI mode
20
Fixed
Yellow Bang may be seen in Microsoft Windows Server 2008* Device manager when using
ASR26XXFHLPR riser
21
No Fix
Firmware will detect a missing server board battery as present and good
22
Fix
Server board cannot detect a 10Gb or QDR IB I/O Module without a PCI Riser installed