Service Guide

Intel
®
Server System SR2612UR Service Guide 21
Configuration Jumpers
Jumper Name Jumper Purpose
A. Serial Port Configuration
(J9A1)
If pins 1-2 are jumpered, the DCD to DTR mode is enabled. These
pins should be jumpered on 3-4 to operate in the DSR to DTR
(default) mode.
B. BMC Force Update
(J1H2)
If pins 2-3 are jumpered, the Integrated BMC Force Update Mode is
enabled. These pins should be jumpered on 1-2 for normal system
operation.
C. BIOS Default (J1E7) If pins 2-3 are jumpered, the BIOS settings are cleared on the next
reset. These pins should be jumpered on 1-2 for normal operation.
D. Password Clear (J1E8) If pins 2-3 are jumpered, administrator and user passwords are
cleared within five to ten seconds after the system is powered on.
These pins should be jumpered on 1-2 for normal system
operation.
AF002832
J1D4
BIOS Recover
2
3
Normal
Recover
J1E8
Password Clear
2
3
Protect
Clear
J1E7
BIOS Default
2
3
Normal
Set
Default
J1H2
BMC Force Update
2
3
Disable
Enable
J9A1
Serial Port
Configuration
34
2
DCD to DTR
DSR to DTR
(factory default)
E
D
C
B
A