Service Guide
Intel
®
Server System SR2612UR Service Guide 119
AC Power
• Input voltage: Auto ranging, 90-264VAC
• Input frequency: 47-63 Hz
• Power factor correction: Per EN61000-3-2
• Input current: 8.8 Amps RMS max @ 100VAC
• Output power: 760 W peak
• Efficiency: 91% @ 230VAC, 50% load
• Variable speed “smart fans”
Supported Options
• One DVD drive
• Up to five PCI-E expansion cards
• Up to two 2.5-inch internal SATA drives
Operating Environment
• Temperature: 0° to 35°C
• Temperature gradient: 20°C per hour
• Relative humidity: 10 to 80 percent (non-condensing)
• Humidity gradient: 10% per hour
• Altitude: -200 to 10,000 ft.
• Shock: 5G at 11ms, 1/2 sine wave pulse
• Vibration: 0.15G at 5Hz to 400Hz
• Acoustics: 7 Bels at normal operation tested to ISO7779
Non-Operating Environment
• Temperature: -40° to 70°C
• Relative humidity: 5% to 95% (non-condensing)
• Altitude: -200 to 40,000 ft.
• Shock: 10G at 11ms, 1/2 sine wave pulse
• Vibration: 0.5G at 5Hz to 400Hz