Technical Product Specification
7BIntel® Local Control Panel Intel®
Server System SR2600UR TPS
78 Intel order number E45274-011 Revision 1.8
Color
State
Criticality
Description
Amber
Blink
Non-critical
Non-fatal alarm – system is likely to fail
Including, but not limited to:
Critical voltage threshold crossed
VRD hot asserted
Minimum number of fans necessary to cool the system are not
present or have failed
In non-sparing and non-mirroring mode if the threshold of ten
correctable errors is crossed within the window
Amber Solid on Critical, non-
recoverable
Fatal alarm – system has failed or shut down
Including, but not limited to:
DIMM failure when there is one DIMM present, no good
memory present
Run-time memory uncorrectable error in non-redundant mode
IERR signal asserted
Processor 1 missing
Temperature (e.g., CPU ThermTrip, memory TempHi, critical
threshold crossed)
No power good – power fault
Processor configuration error (e.g., processor stepping
mismatch)
8.1.3 Drive Activity LED
The drive activity LED on the front panel indicates drive activity from the on-board hard disk
controllers. The Intel
®
Server Board S5520UR also provides a header giving access to this LED
for add-in controllers.
8.1.4 System Identification LED
The blue system identification LED is used to help identify a system for servicing. This is
especially useful when the system is installed in a high-density rack or cabinet that is populated
with several similar systems.
The blue system ID LED can be illuminated using one of the following mechanisms:
By pressing the system ID button on the system control panel, the ID LED displays a
solid blue color until the button is pressed again.
By issuing the appropriate hex IPMI system identify value, the ID LED either blinks blue
for 15 seconds and turns off or blinks indefinitely until the appropriate hex IPMI system
identify value is issued to turn it off.