Technical Product Specification

Intel®
Server System SR2600UR TPS 9BRegulatory and Certification Information
Revision 1.8 Intel order number E45274-011
93
Regulatory Compliance
Country
Marking
注意:
设备包括多条电源系统电缆。为避免遭受电击,在进行维
修之前应断开两(2)条电源系统电缆。
Traditional Chinese:
注意:
本設備包括多條電源系統電纜。為避免遭受電擊,在進行維
修之前應斷開兩(2)條電源系統電纜。
German:
Dieses Geräte hat mehr als ein Stromkabel. Um eine
Gefahr des elektrischen Schlages zu verringern trennen sie
beide (2) Stromkabeln bevor Instandhaltung.
Nordic Countries Connection to
Proper Ground
Outlet
“WARNING:”
“Apparaten skall anslutas till jordat uttag, när den ansluts
till ett nätverk.”
“Laite on liitettävä suojamaadoituskoskettimilla varustettuun
pistorasiaan.”
“Connect only to a properly earth grounded outlet.”
Safety
Stand-by power
11.3 Rack Mount Installation Guidelines
Anchor the equipment rack:
The equipment rack must be anchored to an unmovable support to
prevent it from falling over when one or more servers are extended in front of the rack on slides.
You must also consider the weight of any other device installed in the rack. A crush hazard
exists should the rack tilt forward which could cause serious injury.
Temperature:
The temperature, in which the server operates when installed in an equipment
rack, must not go below 5 °C (41 °F) or rise above 40 °C (104 °F). Extreme fluctuations in
temperature can cause a variety of problems in your server.
Ventilation:
The equipment rack must provide sufficient airflow to the front of the server to
maintain proper cooling. The rack must also include ventilation sufficient to exhaust a maximum
of 1023 BTU's (British Thermal Units) per hour for the server. The rack selected and the
ventilation provided must be suitable to the environment in which the server will be used.
If AC power supplies are installed:
Mains AC power disconnection:
The AC power cord(s) is considered the mains disconnect for
the server and must be readily accessible when installed. If the individual server power cord(s)
will not be readily accessible for disconnection then you are responsible for installing an AC
power disconnect for the entire rack unit. This main disconnect must be readily accessible, and
it must be labeled as controlling power to the entire rack, not just to the server(s).
Grounding the rack installation:
To avoid the potential for an electrical shock hazard, you must
include a third wire safety ground conductor with the rack installation. If the server power cord is