Technical Product Specification
Intel® Server Board S5520UR and S5520URT TPS 4BBIOS Setup Utility
Revision 1.9 Intel order number E44031-012
77
Table 27. Setup Utility — Server Management Configuration Screen Fields
Setup Item
Options
Help Text
Comments
Assert NMI on SERR
Enabled
Disabled
On SERR, generate an NMI and log an error.
Note: [Enabled] must be selected for the Assert NMI
on PERR setup option to be visible.
Assert NMI on PERR
Enabled
Disabled
On PERR, generate an NMI and log an error.
Note: This option is only active if the Assert NMI on
SERR option is [Enabled] selected.
Resume on AC
Power Loss
Stay Off
Last state
Reset
System action to take on AC power loss recovery.
[Stay Off] - System stays off.
[Last State] - System returns to the same state before
the AC power loss.
[Reset] - System powers on.
Clear System Event
Log
Enabled
Disabled
If enabled, clears the System Event Log. All current
entries will be lost.
Note: This option is reset to [Disabled] after a reboot.
FRB-2 Enable
Enabled
Disabled
Fault Resilient Boot (FRB).
If enabled, the BIOS programs the BMC watchdog
timer for approximately 6 minutes. If the BIOS does
not complete POST before the timer expires, the BMC
resets the system.
O/S Boot Watchdog
Timer
Enabled
Disabled
If enabled, the BIOS programs the watchdog timer
with the timeout value selected. If the OS does not
complete booting before the timer expires, the BMC
resets the system and an error is logged.
Requires OS support or Intel Management Software.
O/S Boot Watchdog
Timer Policy
Power Off
Reset
If the OS boot watchdog timer is enabled, this is the
system action taken if the watchdog timer expires.
[Reset] - System performs a reset.
[Power Off] - System powers off.
Grayed out when O/S Boot
Watchdog Timer is
disabled.
O/S Boot Watchdog
Timer Timeout
5 minutes
10 minutes
15 minutes
20 minutes
If the OS watchdog timer is enabled, this is the
timeout value used by the BIOS to configure the
watchdog timer.
Grayed out when O/S Boot
Watchdog Timer is
disabled.
Plug & Play BMC
Detection
Enabled
Disabled
If enabled, the BMC is detectable by OSs that support
plug and play loading of an IPMI driver. Do not enable
if your OS does not support this driver.
ACPI 1.0 Support
Enabled
Disabled
[Enabled] - Publish ACPI 1.0 version of FADT in Root
System Description Table.
May be required for compatibility with OS versions
that only support ACPI 1.0.
Needs to be [Enabled] for
Microsoft Windows 2000*
support.
Console Redirection
View/Configure console redirection information and
settings.
Takes the user to the
Console Redirection
screen.
System Information
View system information
Takes the user to the
System Information
screen.