Technical Product Specification

3BPlatform Management Intel® Server Board S5520UR and S5520URT TPS
Intel order number E44031-012 Revision 1.9
48
4.1 Feature Support
4.1.1 IPMI 2.0 Features
Integrated Baseboard Management Controller (Integrated BMC).
IPMI Watchdog timer.
Messaging support, including command bridging and user/session support.
Chassis device functionality, including power/reset control and BIOS boot flags support.
Event receiver device: The Integrated BMC receives and processes events from other
platform subsystems.
Field replaceable unit (FRU) inventory device functionality: The Integrated BMC
supports access to system FRU devices using IPMI FRU commands.
System event log (SEL) device functionality: The Integrated BMC supports and provides
access to a SEL.
Sensor device record (SDR) repository device functionality: The Integrated BMC
supports storage and access of system SDRs.
Sensor device and sensor scanning/monitoring: The Integrated BMC provides IPMI
management of sensors. It polls sensors to monitor and report system health.
IPMI interfaces.
Host interfaces include system management software (SMS) with receive message
queue support, and server management mode (SMM).
Terminal mode serial interface.
IPMB interface.
LAN interface that supports the IPMI-over-LAN protocol (RMCP, RMCP+).
Serial-over-LAN (SOL).
ACPI state synchronization: The Integrated BMC tracks ACPI state changes that are
provided by the BIOS.
Integrated Baseboard Management Controller (Integrated BMC) self test: The
Integrated BMC performs initialization and run-time self tests, and makes results
available to external entities.
See also the IPMI 2.0 Specification.
4.1.2 Non-IPMI Features
The Integrated BMC supports the following non-IPMI features. This list does not preclude
support for future enhancements or additions.
In-circuit Integrated BMC firmware update.
Fault resilient booting (FRB): FRB2 is supported by the watchdog timer functionality
Chassis intrusion detection and chassis intrusion cable presence detection.
Basic fan control using TControl version 2 SDRs.
Fan redundancy monitoring and support.
Power supply redundancy monitoring and support.
Hot-swap fan support.