Technical Product Specification

Intel® Server Board S5520UR and S5520URT TPS Appendix C: Management Engine Generated SEL Event Messages
Revision 1.9 Intel order number E44031-012
149
=5..255 Reserved
Byte 7 Event Data 3
=<Extended error code. Should be used when reporting an error to the
support>
Table 86. Node Manager Health Event
Node Manager Health
Event
Request
Byte 1 - EvMRev
=04h (IPMI2.0 format)
Byte 2 Sensor Type
=DCh (OEM)
Byte 3 Sensor Number
(Node Manager Health sensor)
Byte 4 Event Dir | Event Type
[0:6] Event Type
= 73h (OEM)
[7] Event Dir
=0 Assertion Event
Byte 5 Event Data 1
[0:3] Health Event Type
=02h Sensor Node Manager
[4:5]=10b OEM code in byte 3
[6:7]=10b OEM code in byte 2
Byte 6 Event Data 2
[0:3] Domain Id (Currently, supports only one domain, Domain 0)
[4:7] Error type
=0-9 - Reserved
=10 Policy Misconfiguration
=11 Power Sensor Reading Failure
=12 Inlet Temperature Reading Failure
=13 Host Communication error
=14 Real-time clock synchronization failure
=15Reserved
Byte 7Event Data 3
if error indication = 10 <PolicyId>
if error indication = 11 <PowerSensorAddress>
if error indication = 12 <InletSensorAddress>
Otherwise set to 0.