Technical Product Specification

Intel® Server Board S5520UR and S5520URT TPS Appendix B: Integrated BMC Sensor Tables
Revision 1.9 Intel order number E44031-012
147
Sensor Name
Sensor #
Platform
Applicability
Sensor Type
Event/Readin
g Type
Event Offset
Triggers
Contrib. To
System Status
Assert/De
-assert
Readable
Value/Off
sets
Event
Data
Rearm
Stand-
by
P2 VRD Temp 67h
Dual
processor
only
Temperature
01h
Digital
Discrete
05h
01 - Limit
exceeded
Fatal
As and
De
Trig Offset M
CATERR 68h All
Processor
07h
Digital
Discrete
03h
01 State
Asserted
Non-fatal
As and
De
Trig Offset M
CPU Missing 69h All
Processor
07h
Digital
Discrete
03h
01 State
Asserted
Non-fatal
As and
De
Trig Offset M
IOH Thermal Trip 6Ah All
Temperature
01h
Digital
Discrete
03h
01 State
Asserted
Fatal
As and
De
Trig Offset M