Technical Product Specification

Appendix B: Integrated BMC Sensor Tables Intel® Server Board S5520UR and S5520URT TPS
Intel order number E44031-012 Revision 1.9
146
Sensor Name
Sensor #
Platform
Applicability
Sensor Type
Event/Readin
g Type
Event Offset
Triggers
Contrib. To
System Status
Assert/De
-assert
Readable
Value/Off
sets
Event
Data
Rearm
Stand-
by
PS1 Current Out 54h
Chassis-
specific
Power
Supply
08h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog R, T A X
PS2 Current Out 55h
Chassis-
specific
Power
Supply
08h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog R, T A X
PS1 Temperature 56h
Chassis-
specific
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog R, T A X
PS2 Temperature 57h
Chassis-
specific
Temperature
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog R, T A X
P1 Status 60h All
Processor
07h
Sensor
Specific
6Fh
01 - Thermal trip Fatal
As and
De
Trig Offset M
X
07 - Presence OK
P2 Status 61h
Dual
processor
only
Processor
07h
Sensor
Specific
6Fh
01- Thermal trip Fatal
As and
De
Trig Offset M
X
07 - Presence OK
P1 Therm Margin 62h All
Temperature
01h
Threshold
01h
Analog
P2 Therm Margin 63h
Dual
processor
only
Temperature
01h
Threshold
01h
Analog
P1 Therm Ctrl % 64h All
Temperature
01h
Threshold
01h
[u] [c] Non-fatal
As and
De
Analog Trig Offset A
P2 Therm Ctrl % 65h
Dual
processor
only
Temperature
01h
Threshold
01h
[u] [c] Non-fatal
As and
De
Analog Trig Offset A
P1 VRD Temp 66h All
Temperature
01h
Digital
Discrete
05h
01 - Limit
exceeded
Fatal
As and
De
Trig Offset M