Technical Product Specification
Intel® Server Board S5520UR and S5520URT TPS Appendix B: Integrated BMC Sensor Tables
Revision 1.9 Intel order number E44031-012
145
Sensor Name
Sensor #
Platform
Applicability
Sensor Type
Event/Readin
g Type
Event Offset
Triggers
Contrib. To
System Status
Assert/De
-assert
Readable
Value/Off
sets
Event
Data
Rearm
Stand-
by
04 - Non-red:
suff from insuff
Degraded
05 - Non-red:
Insufficient
Non-fatal
06 - Redun
degrade from full
Degraded
07 – Redun
degrade from
non-redundant
Degraded
PS1 Status 50h
Chassis-
specific
Power
Supply
08h
Sensor
Specific
6Fh
00 - Presence OK
As and
De
– Trig Offset A
01 - Failure Degraded
X
02 – Predictive
Failure
Degraded
03 - A/C lost Degraded
06 –
Configuration
error
OK
PS2 Status 51h
Chassis-
specific
Power
Supply
08h
Sensor
Specific
6Fh
00 - Presence OK
As and
De
– Trig Offset A
01 - Failure Degraded
X
02 – Predictive
Failure
Degraded
03 - A/C lost Degraded
06 –
Configuration
error
OK
PS1 Power In 52h
Chassis-
specific
Power
Supply
08h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog R, T A X
PS2 Power In 53h
Chassis-
specific
Power
Supply
08h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog R, T A X