Technical Product Specification

Appendix B: Integrated BMC Sensor Tables Intel® Server Board S5520UR and S5520URT TPS
Intel order number E44031-012 Revision 1.9
144
Sensor Name
Sensor #
Platform
Applicability
Sensor Type
Event/Readin
g Type
Event Offset
Triggers
Contrib. To
System Status
Assert/De
-assert
Readable
Value/Off
sets
Event
Data
Rearm
Stand-
by
Server board Temp 20h All
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog R, T A X
IOH Temp 21h All
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog R, T A X
Front Panel Temp 22h All
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog R, T A X
MEM P1 THRM
MRGN
23h All
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog R, T A X
MEM P2 THRM
MRGN
24h
Dual
processor
only
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog R, T A X
Fan Tach Sensors 30h39h
Chassis-
specific
Fan
04h
Threshold
01h
[l] [c,nc]
nc =
Degraded
c = Non-
fatal
2
As and
De
Analog R, T M
Fan Present Sensors 40h45h
Chassis-
specific
Fan
04h
Generic
08h
01 - Device
inserted
OK
As and
De
-
Triggered
Offset
Auto
Fan Redundancy
46h
Chassis-
specific
Fan
04h
Generic
0Bh
00 - Fully
redundant
OK
As and
De
Trig Offset A
01 - Redundancy
lost
Degraded
X
02 - Redundancy
degraded
Degraded
03 - Non-red:
suff res from
redund
Degraded