Technical Product Specification

Intel® Light-Guided Diagnostics Intel® Server Board S5520UR and S5520URT TPS
Intel order number E44031-012 Revision 1.9
122
Color
State
Criticality
Description
Redundancy loss such as power supply or fan. This does not
apply to non-redundant subsystems.
PCI Express* link errors
CPU failure/disabled if there are two processors and one of
them fails.
Fan alarm Fan failure. Number of operational fans should be
more than the minimum number needed to cool the system.
Non-critical threshold crossed Temperature and voltage.
Other degraded events (see Appendix B).
Amber
Blink
Non-critical
Non-fatal alarm system is likely to fail
Critical voltage threshold crossed.
VRD hot asserted.
Minimum numbers of fans to cool the system are not present
or have failed.
In a non-mirroring mode, if the threshold of ten correctable
errors is crossed within the window.
Other non-critical events (see Appendix B).
Amber
Solid on
Critical, non-
recoverable
Fatal alarm system has failed or shut down
DIMM failure when there is one DIMM present and no good
memory is present.
Run-time memory uncorrectable error in non-redundant mode.
IERR signal asserted.
Processor 1 missing
Temperature (e.g., CPU ThermTrip, memory TempHi, critical
threshold crossed).
No power good power fault.
Processor configuration error (for instance, processor stepping
mismatch).
Other critical or non-recoverable events (see Appendix B).