Technical Product Specification

Intel® Server Board S5520UR and S5520URT TPS Connector/Header Locations and Pin-outs
Revision 1.9 Intel order number E44031-012
113
When the server board is integrated into an Intel
®
Server System with fixed hard drives, system
fan monitoring is supported through a custom 26-pin connector with the pin-out defined in the
following table.
Table 70. Server Board-to-System Fan Board Connector Pin-out (Intel
®
Chassis Only)
Pin Definition
Pin #
Pin Definition
FAN_PWM_CPU1
1 2
FAN_PWM_CPU2
FM_FAN_D_PRSNT1_N
3 4
FAN_IO_PWM
FM_FAN_D_PRSNT3_N
5 6
FM_FAN_D_PRSNT2_N
FM_FAN_D_PRSNT5_N
7 8
FM_FAN_D_PRSNT4_N
Empty Connector Key
9 10
LED_FAN1_FAULT
LED_FAN2_FAULT 11 12 LED_FAN3_FAULT
LED_FAN4_FAULT
13 14
LED_FAN5_FAULT
FAN_TACH1_H7
15 16
FAN_TACH2_H7
FAN_TACH3_H7 17 18 FAN_TACH4_H7
FAN_TACH5
19 20
FAN_TACH6
FAN_TACH7
21 22
FAN_TACH8
PCI_FAN_TACH9 23 24 CONN_PIN24_R
PCI_FAN_TACH10
25 26
FM_SIO_TEMP_SENSOR
Note: Intel Corporation server boards support peripheral components and contain a number of
high-density VLSI and power delivery components that need adequate airflow to cool. Intel
®
’s
own chassis are designed and tested to meet the intended thermal requirements of these
components when the fully integrated system is used together. It is the responsibility of the
system integrator that chooses not to use Intel
®
developed server building blocks to consult
vendor datasheets and operating parameters to determine the amount of airflow required for
their specific application and environmental conditions. Intel Corporation cannot be held
responsible if components fail or the server board does not operate correctly when used outside
any of their published operating or non-operating limits.