Technical Product Specification

Intel® Server System SR2625UR TPS Standard Control Panel
Revision 1.8 Intel order number E46130-010
73
Color
State
Criticality
Description
Amber
Blink
Non-critical
Non-fatal alarm system is likely to fail.
Including, but not limited to:
Critical voltage threshold crossed.
VRD hot asserted.
Minimum number of fans to cool the system are not present or
have failed.
In non-sparing and non-mirroring mode if the threshold of ten
correctable errors is crossed within the window.
Amber
Solid on
Critical, non-
recoverable
Fatal alarm system has failed or shut down.
Including, but not limited to:
DIMM failure when there is one DIMM present and no good
memory is present.
Run-time memory uncorrectable error in non-redundant mode.
IERR signal asserted.
Processor 1 missing.
Temperature (e.g. CPU ThermTrip, memory TempHi, critical
threshold crossed)
No power good power fault.
Processor configuration error (e.g. processor stepping mismatch).
7.2.3 Drive Activity LED
The drive activity LED on the front panel indicates drive activity from the on-board hard disk
controllers. The Intel
®
Server Board S5520UR also provides a header giving access to this LED
for add-in controllers.
7.2.4 System Identification LED
The blue system identification LED is used to help identify a system for servicing. This is
especially useful when the system is installed in a high-density rack or cabinet that is populated
with several similar systems.
The blue system ID LED can be illuminated using one of the following mechanisms:
By pressing the system ID button on the system control panel, the ID LED displays a
solid blue color until the button is pressed again.
By issuing the appropriate hex IPMI system identify value, the ID LED either blinks blue
for 15 seconds and turns off or blinks indefinitely until the appropriate hex IPMI system
identify value is issued to turn it off.