Technical Product Specification
Peripheral and Hard Drive Subsystem Intel® Server System SR2625UR TPS
Intel order number E46130-010 Revision 1.8
64
6.4.2.4.1 Intel
®
RAID Activation Key
The Intel
®
RAID Activation Key enables the full intelligent SAS Hardware RAID solution. The
activation key plugs directly into a connector (J1A10) on the midplane board. With no RAID
activation key installed, only SAS Software RAID levels 0, 1, and 10 are supported.
6.4.2.4.2 Intel
®
RAID Cache support
To further enable support for hardware RAID, the active midplane provides a 244-pin mini-
DIMM connector (J8C1), supporting a single registered ECC non-parity DDR2-400 MHz Mini-
DIMM to provide Intel
®
RAID cache. Supported mini-DIMM capacities range from 128 MB
to 1 GB.
Note: For a list of Intel
®
validated mini-DIMMs, use the Server Configurator Tool available at
http://serverconfigurator.intel.com/default.aspx.
6.4.2.4.3 Intel
®
RAID Smart Battery Backup Module
With an Intel
®
RAID Smart Battery Backup module installed, data loss is prevented when data
is still present in the RAID Cache Module and power is unexpectedly lost. Depending on the
cache module capacity used, the battery backup unit can provide 48 to 72 hours of battery
backup power to allow data stored in the RAID cache to be processed. A 2x10 connector (J9A2)
is used to attach the battery backup unit to the midplane. For details, see Table 31.
6.5 Hot-swap SAS/SATA Backplane
The SR2625 system supports its own multifunctional SAS/SATA backplane with the
following features:
Vitesse VSC410 enclosure management controller
o External non-volatile Flash ROM
o Four I
2
C interfaces
o Compliance with SCSI Accessed Fault Tolerant Enclosures (SAF-TE)
specification
o Compliance with Intelligent Platform Management Interface (IPMI)
Eight 2.5-inch compatible hot-swap hard drive connectors
Power for an optional tape drive or two additional 2.5-inch SAS/SATA hard drives
Hard Drive Status and Fault LEDs for each hard drive connector
Card edge connectors for most interconnects, including:
o Midplane
o Control Panel
o Slimline SATA Optical Drive
Temperature Sensor
FRU EEPROM
One 2x4-pin Power Connector