Technical Product Specification
Environmental Specifications Intel® Server System SR2625UR TPS
Intel order number E46130-010 Revision 1.8
88
10. Environmental Specifications
10.1 System Level Environmental Limits
The following table defines the system level operating and non-operating environmental limits.
Table 56. System Environmental Limits Summary
Parameter
Limits
Operating Temperature
+10°C to +35°C with the maximum rate of change not to exceed 10°C per hour
Non-Operating
Temperature
-40°C to +70°C
Non-Operating Humidity
90%, non-condensing at 35°C
Acoustic noise
Sound power: 7.0 BA in an idle state at typical office ambient temperature. (23
+/- 2 degrees C)
Shock, operating
Half sine, 2 g peak, 11 milliseconds
Shock, unpackaged
Trapezoidal, 25 g, velocity change 136 inches/second (≧40 lbs to < 80 lbs)
Shock, packaged
Non-palletized free fall in height 24 inches (≧40 lbs to < 80 lbs)
Vibration, unpackaged
5 Hz to 500 Hz, 2.20 g RMS random
Shock, operating
Half sine, 2 g peak, 11 milliseconds
ESD
+/-15 KV except I/O port +/- 8 KV per Intel
®
Environmental test specification
System Cooling
Requirement in BTU/Hr
2550 BTU/hour
10.2 Serviceability and Availability
The system is designed to be serviced by qualified technical personnel only.
The desired Mean Time To Repair (MTTR) of the system is 30 minutes, including diagnosis of
the system problem. To meet this goal, the system enclosure and hardware have been
designed to minimize the MTTR.
The following table defines the maximum time needed by a trained field service technician to
perform the listed system maintenance procedures, after diagnosing the system and identifying
the failed component.
Table 57. Time Estimate for System Maintenance Procedures
Activity
Time Estimate
Remove cover
1 min
Remove and replace hard disk drive
2 min
Remove and replace power supply module
1 min
Remove and replace system fan
2 min
Remove and replace backplane board
6 min
Remove and replace control panel module
1 min
Remove and replace server board
8 min