Service Guide
Intel
®
Server System SR1625UR Service Guide 73
Figure 61. Installing the SATA Cables
b. If you connect the SATA cables from the passive midplane to the add-in card,
also install the 3-pin white cable between the HBA connector on the midplane
and the add-in card to enable fault LED control.
Note: Do NOT connect the HBA cable in a system with an active midplane or when
using the SATA connectors on the server board to connect the hard drive SATA
cables.
8. Install the bridge board as follows:
a. Open the retention clips on both ends.
b. Insert the bridge board into the bridge board connector on the midplane and
server board.
c. Close the retention clips on both ends to hold the bridge board in place.
9. Install the processor air duct. For instructions, see “Installing the Processor Air
Duct” on page 49.
10. Install the PCI riser assembly into the server system. For instructions, see
“Installing the PCI Riser Assembly” on page 44.
Passive
Midplane
Power Distribution
Board Cover
A
B
0
3
2
1
4
5
Power Supply
Cable
Retention
Ta b
4
5
6
7
1
2
3
Passive Midplane
SATA Connectors
A
0
Server
Board
AF002843