Server System SR1625UR Service Guide 65
Figure 51. Installing the I/O Expansion Module to the Server System
7. Install the processor air duct. For instructions, see “Installing the Processor Air
Duct” on page 49.
8. Install the PCI riser assembly into the server system. For instructions, see
“Installing the PCI Riser Assembly” on page 44.
Removing the I/O Expansion Module(s)
To remove the I/O expansion module, follow these steps:
1. Remove the PCI riser assembly. For instructions, see “Removing the PCI Riser
Assembly” on page 43.
2. Remove the processor air duct. For instructions, see “Removing the Processor Air
Duct” on page 48.
3. Disconnect the I/O expansion module from the server board connector and the
standoffs and remove the module out of the server system (see letter “A” in
Figure 52).
4. Remove the standoffs from the server board (see letter “B” in Figure 52).
1-Socket
I/O Exp. Module
Standoff
Hole
2-Socket
I/O Exp. Module
Server Board
I/O Connector 1
A
B
C
Filler Panels
Snap
Standoff
AF002855