Service Guide
52 Intel
®
Server System SR1625UR Service Guide
Removing DIMMs
To remove a DIMM, follow these steps:
1. Remove the PCI riser assembly. For instructions, see “Removing the PCI Riser
Assembly” on page 43.
2. Remove the processor air duct. For instructions, see “Removing the Processor Air
Duct” on page 48.
3. Locate the DIMM sockets (see Figure 35).
4. Gently spread the retaining clips at each end of the socket. The DIMM lifts from
the socket.
5. Holding the DIMM by the edges, lift it from the socket, and store it in an anti-static
package.
Installing and Removing the Processor
Caution: Processor must be appropriate: You may damage the server board if you install a
processor that is inappropriate for your server. See “Additional Information and
Software” on page 3 for a web link to the list of compatible processor(s).
Caution: ESD and handling processors: Reduce the risk of electrostatic discharge (ESD) damage to
the processor by doing the following: (1) Touch the metal chassis before touching the
processor or server board. Keep part of your body in contact with the metal chassis to
dissipate the static charge while handling the processor. (2) Avoid moving around
unnecessarily.
Installing the Processor
To install a processor, follow these steps:
1. Remove the PCI riser assembly. For instructions, see “Removing the PCI Riser
Assembly” on page 43.
2. Remove the processor air duct. For instructions, see “Removing the Processor Air
Duct” on page 48.
3. Remove the heatsink, if installed. For instructions, see “Removing the Heatsink” on
page 57.
4. Locate the processor socket.
5. Push the lever handle down and away from the socket to release it (see letter “A” in
Figure 36).
6. Rotate the lever open all the way (see letter “B” in Figure 36).