Server System SR1625UR Service Guide 31
Rack Mount Options
Your Intel
®
Server System SR1625UR can be mounted into a rack. Intel provides the
following three options to mount this server system into a rack:
• Fixed mount relay rack/cabinet mount kit: This kit can be configured to mount the
system into either a 2-post rack or 4-post cabinet.
• Tool-less sliding rail kit: This kit is used to mount the chassis into a standard (19
inches by upto 30 inches deep) EIA-310D compatible server cabinet. An optional
cable management arm can be used with this kit.
• Basic three-quarter extension sliding rail kit: This kit is used to mount the chassis
into a standard (19 inches by upto 30 inches deep) EIA-310D compatible server
cabinet.
When installing the chassis into a rack, Intel recommends you install systems from the
bottom of the rack to the top. In other words, install the first system in the rack into the
bottom position of the rack, the second system in the second position from the bottom, and
so on. For instructions on installing your chassis into a rack, see “Removing and Installing
from a Rack” on page 35. These instructions are also included in each rackmount
option kit.