Service Guide
10 Intel
®
Server System SR1625UR Service Guide
Intel
®
Light-Guided Diagnostics
The server system contains the following diagnostic LEDs, each providing the following
functions:
• The System Status LED on the front and back panels (see Figure 3 and Figure 6)
shows the overall health of the system (green, blinking green, blinking amber,
amber, off) .
• The System Identification LED on the front and back panel (see Figure 3 and
Figure 6) helps identify the server from among several servers. The ID LED is off
by default, and blue when activated by button or software.
• DIMM Fault LEDs on the server board (see Figure 3) help identify failed and failing
DIMM slots. The DIMM fault LEDs turn on (amber) if there is a DIMM fault.
• POST Code Diagnostic LEDs on the server board (see Figure 3) change color or
state (off, green, red, amber) according to the POST sequence.
• The 5V-STBY LED on the server board (see Figure 3) is illuminated (green) when
AC power is applied.
• Fan Fault LEDs on the passive midplane (in the passive system - see Figure 4) or
active midplane (in the active system - see Figure 5) help identify failed and failing
fans. The fan fault LEDs turn on (amber) if there is a fan fault.