Service Guide
Intel
®
Server System SR1600UR Service Guide 105
System Environmental Specifications
Table 7. System Environmental Specifications
Temperature
Non-operating
Operating
-40° to 70°C.
10°C to 35°C with the maximum rate of change not to exceed 10°C per
hour
Humidity
Non-operating 90% relative humidity (non-condensing) at 35°C.
Shock
Operating
Packaged
Unpackaged
2.0 g, 11 msec, half sine
Non-palletized free fall in height 24 inches (> 40 lbs to < 80 lbs)
Trapezoidal, 25 g, velocity change 136 inches/sec (> 40 lbs to < 80 lbs)
Acoustic noise Sound Power: 7.0 BA in an idle state at typical office ambient temperature
(23 +/- 2°C).
Electrostatic
discharge (ESD)
+/-15 KV except I/O port +/- 8 KV per Intel
®
Environment test specification.
System Cooling
Requirement in
BTU/Hr
2550 BTU/Hr