Appendix A: Technical Reference
600-W Single Power Supply Input Voltages
The power supply must operate within all specified limits over the input voltage range
shown in the following table.
Table 5. Power Supply Input Voltages
Note: Maximum input current at low input voltage range is measured at 90 VAC, at maximum
load.
Maximum input current at high input voltage range is measured at 180 VAC, at maximum
load.
This is not to be used for determining agency input current markings.
Maximum rated input current is measured at 100 VAC and 200 VAC.
Parameter Minimum Rated Maximum
Startup
VAC
Power-off
VAC
Maximum
Input AC
Current
Maximum
Rated Input
AC Current
Voltage
(110)
90 V
rms
100-127 V
rms
140 V
rms
85 VAC +/-
4 VAC
75 VAC +/
-5 VAC
9.5 A
rms
1,3
8.55 A
rms
4
Voltage
(220)
180 V
rms
200-240 V
rms
264 V
rms
4.75 A
rms
2,3
4.3 A
rms
4
Frequency 47 Hz 50/60 Hz 63 Hz