8.1.2 System Status LED
Table 43. Control Panel LED Operation
Color
State
Criticality
Description
Off
N/A
Not ready
AC power off
Green
Solid on
Ok
System booted and ready
Green
Blink
Degraded
System degraded
Unable to use all of the installed memory (more than one
DIMM installed).
Correctable errors over a threshold of ten and migrating
to a spare DIMM (memory sparing). This indicates that
the user no longer has spare DIMMs indicating a
redundancy lost condition. The corresponding DIMM LED
should light up.
In a mirrored configuration, when memory mirroring takes
place and system loses memory redundancy. This is not
covered by the second bullet above.
Redundancy loss such as power supply or fan. This does
not apply to non-redundant subsystems.
PCI Express* link errors.
CPU failure/disabled – if there are two processors and
one of them fails.
Fan alarm – Fan failure. Number of operational fans
should be more than the minimum number needed to
cool the system.
Non-critical threshold crossed – temperature and voltage.
Amber
Blink
Non-critical
Non-fatal alarm – system is likely to fail.
Critical voltage threshold crossed.
VRD hot asserted.
Minimum number of fans to cool the system are not
present or have failed.
In non-sparing and non-mirroring mode, if the threshold
of ten correctable errors is crossed within the window.
Amber
Solid on
Critical, non-
recoverable
Fatal alarm – system has failed or shut down.
DIMM failure when there is one DIMM present and no
good memory is present.
Run-time memory uncorrectable error in non-redundant
mode.
IERR signal asserted.
Processor 1 missing.
Temperature (e.g., CPU ThermTrip, memory TempHi,
critical threshold crossed).
No power good – power fault.
Processor configuration error (e.g.,
processor stepping
mismatch).
8.1.3 Drive Activity LED
The drive activity LED on the front panel indicates drive activity from the on-board hard disk
controllers. The Intel
®
Server Board S5520UR also provides a header giving access to this LED