Service Guide
Intel
®
Server System SR2600UR/SR2625UR Service Guide 57
Installing the Processor Air Duct
Place the processor air duct over the processor socket(s) (see Figure 39). The front edge of
the air duct should contact the fan module. Use caution not to pinch or disengage cables
that may be near or under the air duct.
Figure 39. Installing the Processor Air Duct
Installing and Removing Memory
The silkscreen on the board displays DIMM A1, DIMM A2, DIMM B1, DIMM B2,
DIMM C1, DIMM C2 for DIMMs on CPU socket 1 and DIMM D1, DIMM D2, DIMM
E1, DIMM E2, DIMM F1, DIMM F2 for DIMMs on CPU socket 2.
Installing DIMMs
To install DIMMs, follow these steps:
1. Remove the PCI riser assembly. For instructions, see “Removing the PCI Riser
Assembly” on page 50.
2. Remove the processor air duct. For instructions, see “Removing the Processor Air
Duct” on page 56
Processor
Air Duct
AF002957