Service Guide
146 Intel
®
Server System SR2600UR/SR2625UR Service Guide
Warning: Do not exceed a combined power output of 90 Watts for the +5 V and +3.3 V outputs.
Exceeding a combined 90 Watts will overload the power subsystem and may cause the
power supplies to overheat and malfunction.
System Environmental Specifications
The following table defines the system level operating and non-operating
environmental limits.
+12.0 V1 26.0 A 32 A max
+12.0 V2 26.0 A 32 A max
-12.0 V3 112.5% (= 18.0 A) 20 A
+12.0 V4 112.5% (= 18.0 A) 20 A
-12.0 V 125% (= 0.625 A) 400% (= 2.0 A)
Table 6. Power Supply Output Capability
Voltage Minimum OCP Limits Maximum OCP Limits
Table 7. System Environmental Specifications
Temperature
Non-operating
Operating
-40°C to 70°C.
10°C to 35°C with the maximum rate of change not to exceed 10°C per
hour.
Humidity
Non-operating 90% relative humidity (non-condensing) at 28°C.
Shock
Operating
Packaged
Unpackaged
2.0 g peak, 11 msec, half sine.
Non-palletized free fall in height 24 inches (> 40 lbs to < 80 lbs)
Operational after an 18" free fall.
Trapezoidal, 25 g, velocity change 136 inches/sec.
Vibration
Unpackaged 5 Hz to 500 Hz, 2.20 g RMS random.
Acoustic noise Sound Power: 7.0 BA in an idle state at typical office ambient temperature
(23 +/- 2°C).
Electrostatic
discharge (ESD)
+/-12 KV except I/O port +/- 8 KV per Intel Environment test specification.
System Cooling
Requirement in
BTU/Hr
2550 BTU/Hr