Service Guide
Intel
®
Server System SR2600UR/SR2625UR Service Guide 121
— If no power supply is to be installed, insert a power supply filler panel as shown
in Figure 115.
Figure 115. Installing Power Supply Filler Panel into the Server System
Replacing the Power Distribution Module
To replace the power distribution module, follow these steps:
1. If installed, remove the PCI riser assembly. For instructions, see “Removing the
PCI Riser Assembly” on page 50.
2. If installed, remove the processor air duct. For instructions, see “Removing the
Processor Air Duct” on page 56.
3. Remove the large air baffle. For instructions, see “Removing the Large Air Baffle”
on page 70.
4. Remove the fan module assembly. For instructions, see “Replacing a Fan Module”
on page 128.
5. Disconnect all power cables from the server board, backplane, and midplane.
6. Remove the hot-swap power supply/supplies. For instructions, see step 1 in
“Replacing the Power Supply” on page 121.
7. Remove the two screws to release the module (see letter “A” in Figure 116).
AF000023