Server System SR2600UR/SR2625UR Service Guide 115
Figure 108. Removing the RAID Battery Backup Unit
6. Install the large air baffle. For instructions, see “Installing the Large Air Baffle” on
page 70.
7. Install the processor air duct. For instructions, see “Installing the Processor Air
Duct” on page 57.
8. Install the PCI riser assembly. For instructions, see “Installing the PCI Riser
Assembly” on page 51.
Installing and Removing the Server Board
Removing the Server Board
To remove the server board, follow these steps:
1. If installed, remove the PCI riser assembly. For instructions, see “Removing the
PCI Riser Assembly” on page 50.
2. If installed, remove the processor air duct. For instructions, see “Removing the
Processor Air Duct” on page 56.
3. Remove the bridge board. For instructions, see step 5 in “Removing the Midplane
Board” on page 103.
4. Remove the large air baffle. For instructions, see “Removing the Large Air Baffle”
on page 70.
5. Remove the fan module assembly. For instructions, see “Replacing a Fan Module”
on page 128.
6. Remove the I/O expansion module, if installed. For instructions, see “Removing
the I/O Expansion Module” on page 98.
A
B
Midplane RAID
BBU Connector
Chassis
Tab(2)
Power
Supply
Battery
Backup
Unit
AF002979