Service Guide

Intel
®
Server System SR2600UR/SR2625UR Service Guide 109
Installing the Backplane
To install the backplane, follow these steps:
1. Remove the midplane board. For instructions, see “Removing the Midplane Board”
on page 103.
2. Remove all hot-swap drive carriers, regardless of whether or not a drive is installed
in the carrier. For instructions, see “Removing a SAS or SATA Hot-swap Hard Disk
Drive” on page 74.
3. Depending on your server system, do one of the following:
For Intel
®
Server System SR2600UR, do the following:
a. Hold the backplane only by the edges. Do not push or pull on any components on
the backplane. Set the backplane in place at the front of the server system, with
the sides of the board resting in the guides at the left and right sides of the server
system.
b. Slide the backplane into the server system guides at the left and right sides of the
server system until the pins at the left and right sides of the backplane bracket are
fully inserted into the matching holes in the server system (see letters “A” and
“B” in Figure 103).
Figure 103. Installing the Backplane into the Intel
®
Server System SR2600UR
For Intel
®
Server System SR2625UR, do the following:
a. Hold the backplane only by the edges. Do not push or pull on any components on
the backplane. Set the backplane in place at the front of the server system (see
letter “A” in Figure 104).
AF002975
A
B