Service Guide

98 Intel
®
Server System SR2600UR/SR2625UR Service Guide
5. Install the I/O expansion module filler panel(s) into the system back panel (see
letter “C” in Figure 89).
Figure 89. Removing the I/O Expansion Module from the Server System
6. Install the processor air duct. For instructions, see “Installing the Processor Air
Duct” on page 57.
7. Install the PCI riser assembly into the server system. For instructions, see
“Installing the PCI Riser Assembly” on page 51.
Installing and Removing the Intel
®
Remote
Management Module 3
Installing the Intel
®
RMM3
To install the Intel
®
Remote Management Module 3, follow these steps:
1. Remove the PCI riser assembly. For instructions, see “Removing the PCI Riser
Assembly” on page 50.
2. Remove the processor air duct. For instructions, see “Removing the Processor Air
Duct” on page 56.
1-Socket
I/O Exp. Module
Standoff
Hole
2-Socket
I/O Exp. Module
Snap
Standoff
Server Board
I/O Connector 1
C
B
A
Filler Panels
AF003007