Specification update

Monthly Specification Update Enterprise Platforms and Services Marketing
6
Implication User may see system hang with mentioned configuration.
Status This issue may be fixed in a future RSTe UEFI driver release.
Workaround None.
8.
Microsoft Windows 2003* x86 installation failure under Pass-through
mode of SCU controller
Problem Microsoft Windows Server 2003* x86 installations on SCU RSTe pass-through
mode fail.
Implication User may not able to install Microsoft Windows Server 2003* x86 on mentined
BIOS configuration.
Status This issue may be fixed in a future RSTe driver release.
Workaround None.
9.
System may halt under unsupported configuration in ESRT2 mode
Problem If no Intel
®
C600 RAID upgrade key (any of RKSAS4, RKSAS4R5, RKSAS8,
RKSAS8R5) is installed to enable SAS support capablity under ESRT2 mode
while SAS drivers are used, the system may halt at the boot stage.
Implication User may see a system halt with no RAID keys installed with SAS drivers used
and ESRT2 enabled.
Status This issue may be fixed in a future BIOS release.
Workaround None.
10.
Extra events may be seen in the System Event Log (SEL) during system
global reset
Problem The BMC may sporadically log extra reset event during a system DC reset
(global reset). These events may appear as there is an extra reset during BIOS
POST.
The following SEL entries indicate two resets in a POST process:
Informational event: Pwr Unit Status reports the power unit is powered off or
being powered down.
Informational event: Pwr Unit Status reports the power unit is powered off or
being powered down.