Service Guide
Workstation System Features
Intel® Workstation System SC5650SCWS Service Guide 13
Callout LED Functions
I. DIMM B2 fault LED This LED indicates a fault occurred with the DIMM installed in socket DIMM_B2.
Replace the faulty DIMM.
J. DIMM A1 fault LED This LED indicates a fault occurred with the DIMM installed in socket DIMM_A1.
Replace the faulty DIMM.
K. DIMM A2 fault LED This LED indicates a fault occurred with the DIMM installed in socket DIMM_A2.
Replace the faulty DIMM.
L. Processor 2 fan
fault LED
This LED applies only to workstation systems that use an active heatsink. This LED
indicates a fault occurred with the fan installed on the heatsink for processor 2.
Replace faulty unit.
M. DIMM D2 fault LED This LED indicates a fault occurred with the DIMM installed in socket DIMM_D2.
Replace the faulty DIMM.
N. DIMM D1 fault LED This LED indicates a fault occurred with the DIMM installed in socket DIMM_D1.
Replace the faulty DIMM.
O. DIMM E2 fault LED This LED indicates a fault occurred with the DIMM installed in socket DIMM_E2.
Replace the faulty DIMM.
P. DIMM E1 fault LED This LED indicates a fault occurred with the DIMM installed in socket DIMM_E1.
Replace the faulty DIMM.
Q. DIMM F2 fault LED This LED indicates a fault occurred with the DIMM installed in socket DIMM_F2.
Replace the faulty DIMM.
R. DIMM F1 fault LED This LED indicates a fault occurred with the DIMM installed in socket DIMM_F1.
Replace the faulty DIMM.
S. +5-V Standby LED This LED is green whenever AC power is applied to the system. The system does not
need to be powered on for this LED to be on.
Figure 11. Intel
®
Light-Guided Diagnostics
RAID Support
The Intel
®
Workstation System SC5650SCWS provides an embedded SATA controller that supports both 1.5
Gbps and 3.0 Gbps data transfer rates.
The BIOS Setup Utility provides drive configuration options on the Advanced | Mass Storage Controller
Configuration setup page, some of which affect the ability to configure RAID. The “On-board SATA Controller”
option is enabled by default and when enabled, you can set the “SATA Mode” option to one of the following
four modes:
“Enhanced” – Enhanced Mode supports up to six SATA ports with IDE native Mode.
“Compatibility” – Supports up to four SATA ports [0/1/2/3] with IDE Legacy mode and two SATA ports
[4/5] with IDE Native Mode.
“AHCI” – Supports all SATA ports using the Advanced Host Controller Interface.
“SW RAID” – Intel
®
Embedded Workstation RAID Technology II is enabled by “SW RAID” mode. The
Intel
®
Embedded Workstation RAID Technology II feature provides RAID modes 0, 1, and 10.
If RAID 5 is needed, you must install the optional Intel
®
RAID Activation Key AXXRAKSW5 accessory. This
activation key is placed on the SATA_ RAID_5_Key connector located on the left side of the workstation board.