Technical Product Specification
Intel® Workstation System SC5650SCWS TPS Power Sub-system
Revision 1.2
Intel order number: E81822-002
65
4.1.5.3.1 Electrostatic Discharge Susceptibility
The power supply complies with the limits defined in EN 55024: 1998 using the IEC 61000-4-
2:1995 test standard and performance criteria B defined in Annex B of CISPR 24.
4.1.5.3.2 Fast Transient/Burst
The power supply complies with the limits defined in EN55024: 1998 using the IEC 61000-4-
4:1995 test standard and performance criteria B defined in Annex B of CISPR 24.
4.1.5.3.3 Radiated Immunity
The power supply complies with the limits defined in EN55024: 1998 using the IEC 61000-4-
3:1995 test standard and performance criteria A defined in Annex B of CISPR 24.
4.1.5.3.4 Surge Immunity
The power supply is tested with the system for immunity to AC Ringwave and AC Unidirectional
wave, both up to 2kV, per EN 55024:1998, EN 61000-4-5:1995 and ANSI C62.45: 1992.
The pass criteria include: no unsafe operation is allowed under any condition; all power supply
output voltage levels must stay within proper specification levels; no change in operating state
or loss of data during and after the test profile; no component damage under any condition.
The power supply complies with the limits defined in EN55024: 1998 using the IEC 61000-4-
5:1995 test standard and performance criteria B defined in Annex B of CISPR 24.
4.1.5.4 AC Line Fast Transient (EFT) Specification
The power supply meets the EN61000-4-5 directive and any additional requirements in
IEC1000-4-5: 1995 and the Level 3 requirements for surge-withstand capability, with the
following conditions and exceptions:
These input transients do not cause any out-of-regulation conditions, such as overshoot
and undershoot, nor do they cause any nuisance trips of any of the power supply
protection circuits.
The surge-withstand test must not produce damage to the power supply.
The supply meets surge-withstand conditions under maximum and minimum DC-output
load conditions.
4.1.5.5 AC Line Dropout / Holdup
Table 23. AC Line Dropout / Holdup
Output Wattage Loading Holdup time
1000W 75% 20 ms