3.1.3 Enterprise South Bridge Interface (ESI)
One x4 ESI link interface that supports the PCI Express* Gen1 (2.5 Gbps) transfer rate for
connecting Intel
®
ICH10R in the Intel
®
Workstation System SC5650SCWS.
3.1.4 Manageability Engine (ME)
An embedded ARC controller is within the IOH providing the Intel
®
Server Platform Services
(SPS). The controller is also commonly referred to as the Manageability Engine (ME).
3.1.5 Controller Link (CL)
The Controller Link is a private, low-pin count (LPC), low power, communication interface
between the IOH and the ICH10 portions of the Manageability Engine subsystem.
3.2 Processor Support
The Intel
®
Workstation System SC5650SCWS supports one or two Intel
®
Xeon
®
Processor 5500
Series or Intel
®
Xeon
®
Processor 5600 Series with a 4.8 GT/s, 5.86 GT/s, or 6.4 GT/s Intel
®
QPI
link interface and Thermal Design Power (TDP) up to 130 W.
The workstation boards do not support previous generations of the Intel
®
Xeon
®
processors.
For a complete, updated list of supported processors, see:
http://support.intel.com/support/motherboards/server/S5520SC/
. On the Support tab, look for
“Compatibility” and then “Supported Processor List”.
3.2.1 Processor Population Rules
You must populate processors in sequential order. Therefore, you must populate processor
socket 1 (CPU 1) before processor socket 2 (CPU 2).
When only one processor is installed, it must be in the socket labeled CPU1, which is located
near the rear edge of the workstation board. When a single processor is installed, no terminator
is required in the second processor socket.
For optimum performance, when two processors are installed, both must be the identical
revision and have the same core voltage and Intel
®
QPI/core speed.
3.2.2 Mixed Processor Configurations.
The following table describes mixed processor conditions and recommended actions for the
Intel
®
Workstation System SC5650SCWS. Errors fall into one of three categories:
z Halt: If the system can boot, it pauses at a blank screen with the text
“Unrecoverable fatal error found. System will not boot until the error is resolved” and
“Press <F2> to enter setup”, regardless of if the “Post Error Pause” setup option is
enabled or disabled. After entering setup, the error message displays on the Error
Manager screen and an error is logged to the System Event Log (SEL) with the error
code. The system cannot boot unless the error is resolved. The user must replace
the faulty part and restart the system.