Rms2Mh080

14 Intel® Integrated RAID Module RMS2MH080 Hardware User’s Guide
Figure 6. Intel
®
RAID Smart Battery AXXRSBBU7
Note: Only one option can be used at a time. Attempting to install two Smart Batteries may
result in system errors.
Diagnostic Components
Audible Alarm
The audible alarm beeps when a drive fails and also during a rebuild. The drive failure
alarm beeps are:
Degraded array: Short tone, one second on, one second off.
Failed array: Long tone, three seconds on, one second off.
Hot spare commissioned: Short tone, one second on, three seconds off.
The drive failure tones repeat until the problem is corrected, or until the alarm is silenced
or disabled. The alarm can be silenced or disabled on the controllers properties page in
the BIOS Console or by using the failed drive options pane in the Intel
®
RAID Web
Console 2.
Silencing the alarm is temporary. If the cause of failure still exists or if an additional
failure is detected, then the alarm sounds again when the system is rebooted. Disabling the
alarm is persistent across errors and reboots. When the alarm is disabled, a failure does not
cause it to sound until it is re-enabled.
The rebuild alarm tone functions differently. It remains ON during the rebuild. After the
rebuild completes, an alarm with a different tone sounds to signal that the rebuild is
complete. This is a one-time, non-repeating tone.
LED Placement and Function
The Intel
®
Integrated RAID Module RMS2MH080 contains the following LEDs: